Connecting the VP-26 Presentation Matrix Switcher
21
6.8
DIP-Switch Settings
Figure 14
and
Table 6
define the factory default DIP-switch settings
1
:
OFF
ON 1 2 3 4
Figure 14: Default DIP-switch Settings
Table 6: DIP-switch Settings
DIPS
Function
Description
1, 2, 3
Machine #
Determines the number of the machine in the sequence
4 RS-485
TERM
ON for RS-485 Line Termination with 120
Ω
;
OFF for no RS-485 Line Termination
6.8.1 Setting the Machine # DIP-Switches
You can cascade up to eight
VP-26
units. The Machine # determines the
position of a
VP-26
unit, specifying which
VP-26
unit is being controlled
when several
VP-26
units connect to a PC or serial controller. Set the
Machine # on a
VP-26
unit via Setup DIPS 1, 2 and 3, according to
Table 7
.
Table 7: Machine # DIP-switch Settings
Machine
#
DIP-switch
1
2
3
1
Master
OFF OFF OFF
2
OFF OFF ON
3 OFF
ON
OFF
4 OFF
ON
ON
5 ON
OFF
OFF
6 ON
OFF
ON
7
ON ON OFF
8
ON ON ON
1 By default, all dipswitches are set to OFF