Kramer Electronics Ltd.
VP-440
– Protocol 3000
57
SCLR-AS
Functions
Permission
Transparency
Set:
SCLR-AS
End User
Public
Get:
SCLR-AS?
End User
Public
Description
Syntax
Set:
Set the auto sync off timer
#SCLR-AS
␠
P1,P2
␍
Get:
Get the auto sync off timer definition
#SCLR-AS?
␠
P1
␍
Response
Set / Get: ~
nn
@
SCLR-AS
␠
P1,P2….
␍␊
Parameters
P1 (Scaler Number)
–1=Scaler
P2 (Off/On)
– 0=Off; 1=Fast; 2=Slow
Response triggers
Response is sent to the com port from which the
Set
(before execution)
/ Get
command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control device
(button press, device menu and similar) or genlock status was changed
Notes
Sets the Auto Sync features for the selected Scaler
SCLR-AUDIO-DELAY
Functions
Permission
Transparency
Set:
SCLR-AUDIO-DELAY
End User
Public
Get:
SCLR-AUDIO-DELAY?
End User
Public
Description
Syntax
Set:
Set the scaler audio delay
#SCLR-AUDIO-DELAY
␠
P1,P2
␍
Get:
Get the scaler audio delay
#SCLR-AUDIO-DELAY?
␠
P1
␍
Response
Set / Get: ~
nn
@
SCLR-AUDIO-DELAY
␠
P1,P2
␍␊
Parameters
P1 (Audio output number)
–1=Scaler
P2 (Level selection)
– 0=Off; 1=40ms; 2=110ms; 3=150ms
Response triggers
Response is sent to the com port from which the Set (before execution) / Get command was received
After execution, response is sent to all com ports if CMD-NAME was set any other external control device
(button press, device menu and similar) or genlock status was changed
Notes
Sets the audio delay for the selected audio output