background image

 

 

 
 
 
 
 
 

INSTALLATION MANUAL 

 
 

 

 
 

CADDX CONTROLS, INC

1420 NORTH MAIN STREET 

GLADEWATER, TEXAS  75647 

TOLL FREE 800-727-2339 

FAX 903-845-6811 

 

Table of Contents 

 

 

Page 

 

General Description ......................................................................... 2 

6-Position Dip Switch Settings ......................................................... 2  

Enrolling the NX216-E Expander ..................................................... 2  

Wiring the NX216-E ......................................................................... 3 

Terminal Description ........................................................................ 3  

Wiring Diagram ................................................................................ 3  

Default Zone Configurations ............................................................ 4  

Programming Zone Configuration & Partition ............................ 5 - 11 

Specifications............................................................................. Back 

 

 

N

N

E

E

T

T

W

W

O

O

R

R

X

X

 

 

N

N

X

X

2

2

1

1

6

6

-

-

E

E

 

 

Z

Z

O

O

N

N

E

E

 

 

E

E

X

X

P

P

A

A

N

N

D

D

E

E

R

R

 

Summary of Contents for NX216-E

Page 1: ...ntents Page General Description 2 6 Position Dip Switch Settings 2 Enrolling the NX216 E Expander 2 Wiring the NX216 E 3 Terminal Description 3 Wiring Diagram 3 Default Zone Configurations 4 Programmi...

Page 2: ...FF OFF 57 21 ON ON ON OFF OFF 65 96 OFF OFF OFF ON OFF 73 97 ON OFF OFF ON OFF 81 98 OFF ON OFF ON OFF 89 99 ON ON OFF ON OFF 97 100 OFF OFF ON ON OFF 105 101 ON OFF ON ON OFF 113 102 OFF ON ON ON OFF...

Page 3: ...Connect as shown below IF NOT USED CONNECT TO A COM TERMINAL AUX Can be used to power devices directly from the NX216 E Power is coming from the NX8 NX8 E therefore the current draw of these devices...

Page 4: ...eport as user 99 12 INTERIOR FOLLOWER WITH CROSS ZONE ENABLED This zone will be Instant when the system is armed and no entry or exit delay is being timed It is delayed during entry and exit delay tim...

Page 5: ...ABLED This zone will be instant when the system is armed and no entry or exit delay is being timed It is delayed during entry and exit delay times It will send a report if the zone activity time is re...

Page 6: ...ONES 17 24 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 30 ZONES 17 24 PARTITION SELECT Segment 1 2 3 4 5 6 7 8 Zone 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2...

Page 7: ...8 Zone 49 50 51 52 53 54 55 56 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 172 ZONES 57 64 CONFIGURATION GROUP 6 6 6...

Page 8: ...4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 180 ZONES 89 96 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 181 ZONES 89 96 PARTITION...

Page 9: ...2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 188 ZONES 121 128 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 189 ZONES 121 128 P...

Page 10: ...2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 196 ZONES 153 160 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 197 ZONES 153 160 P...

Page 11: ...84 CONFIGURATION GROUP 6 6 6 6 6 6 6 6 203 ZONES 177 184 PARTITION SELECT Segment 1 2 3 4 5 6 7 8 Zone 177 178 179 180 181 182 183 184 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1...

Page 12: ...AW 30mA LOOP RESISTANCE 300 Ohms Maximum LOOP RESPONSE Selectable 50mS or 500mS OPERATING TEMPERATURE 32 to 120 degrees F DIMENSIONS 6 0 Wide 2 125 High 1 0 Deep SHIPPING WEIGHT 2 lbs CADDX CONTROLS I...