SP-1G - Using the SP-1G Menus
19
To set the genlock reference source:
•
Press
▼ or ▲ until
SET1. RefSource SDI
•
Press
◄ or ►
to choose the settings:
SDI
GenlockInput
or
AnalogGenlockInp
•
Press ENTER to save the setting temporarily (until powered down)
6.6.4
Setting the Horizontal and Vertical Timing
Use the horizontal timing to adjust the horizontal delay of an output signal relative
to the reference source signal.
Possible timing values are:
•
-9800nsec to +9800nsec, step 7nsec in 3G HD mode
•
-19600nsec to +19600nsec, step 14nsec in HDTV mode
•
-51800nsec to +51800nsec, step 37nsec in SDTV mode
Default timing is 0nsec.
Negative values advance the output signal, positive values retard the signal.
To speed the adjustment, press and hold the appropriate
◄
or
►
button (repeat
mode). For 16x ultra repeat mode, press and hold the appropriate
◄
or
►
button
while pressing the ENTER button. In this case, the adjusted parameter changes by
steps of 16 units.
To quickly reset to the factory default value, press and hold both
◄
and
►
buttons
together for 1 sec.
To set the horizontal timing:
•
Press
▼ or ▲ u
ntil
SET1 SDI TIMING Horiz
, press
◄
to advance the timing
by the appropriate step and
►
to retard the timing
•
Press ENTER to save the setting temporarily (until powered down)
•
Save the new horizontal timing using the procedure Saving Setups in
Section 6.2