![Kramer SP-11D Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/kramer/sp-11d/sp-11d_user-manual_2000818019.webp)
Communication Protocol
17
9
Communication Protocol
This protocol, which enables RS-232 communication between the
SP-11D
and the PC, uses 4 bytes of information, and data is at 9600 baud.
Table 6: Protocol Definitions
First byte options
DEC
HEX
1 128
80
RESET VIDEO
2 160
A0
READ PARAMETER
3 161
A1
WRITE PARAMETER
4 162
A2
RECALL
5 163
A3
STORE
6 189
BD
IDENTIFY MACHINE
7 33
21
Set (for the rest of commands)
Second byte is the command type
Third byte is the parameter value
Note:
1. When working in HEX, add 80 to the values in the table.
2. When working in DEC, add 128 to the values in the table.
3. All values in the table are in DEC.
Byte 2
Command Description
Byte 3 (parameter value)
0
INPUT FORMAT
0 - CV
1 - YC
2 - YUV
3 - RGB/S
4 - SDI
1
INPUT_STANDARD
0 - PAL B
1 - PAL N
2 - PAL M
3 - NT 3
4 - NT 4
5 - SEC
6 – AUTO
(READ 19 - INPUT_STANDARD_AUTO)
2
SPLITTER
-100 - +100
3
SHARP_H
0 - 15
4
SHARP_V
0 - 15
5
CONTRAST
-100 - +100
6
BRIGHTNESS
-100 - +100
7
VIDEO_GAIN
-100 - +100
8
H_SHIFT
-16 - +15
9
V_SHIFT
-1 - +1
10
Y
-100 - +100
11
U
100 - +100
12
V
100 - +100
13
GREEN
-100 - +100
14
BLUE
-100 - +100
15
RED
-100 - +100
16
COLOR
-100 - +100
17
HUE
-100 - +100
18
COLOR_SPACE
0 - OFF
1 - YUV
2 - RGB
19
INPUT_STANDARD_AUTO
(READ ONLY)
0 - PAL B
1 - PAL N
2 - PAL M
3 - NT 3
4 - NT 4
5 - SEC