The Router Mode Keys
9
7.2 Initializing the RC-IR2
Table 2 describes the initializing sequence:
Table 2: RC-IR2 Initializing Sequence
Press
To
IR LED
Behavior on
the Switcher
Front Panel
See
Section
<->
Select single digit
ON and then OFF 7.3.1
ROUTER
Select the machine number
ON
7.2.1
1 or other
Set the machine number
OFF
Group
Select the Group number
ON
7.2.2
12 or 11 (if the switcher
has one output only
1
) or
other for old protocols
Set the Group number
OFF
AFV/VIDEO/AUDIO
Select AFV to control both video and audio
Select VIDEO to control only video
Select AUDIO to control only audio
Briefly blinks
<- ->
If the controlled switcher has more than 20
inputs/outputs select double digit
ON and then OFF 7.3.1
7.2.1
Assigning the ROUTER Number
To assign the switcher’ s machine
number to the
RC-IR2
, do the following:
1. Point the remote control transmitter at the remote receiver and press the
ROUTER key.
2. Press the digit corresponding to the machine number
2
.
This sets and saves the ROUTER number on the
RC-IR2
.
The assigned machine number must always be identical to the setting on the
machine
7.2.2
Assigning the GROUP Number
After assigning the ROUTER number, you have to assign the GROUP number
To assign the GROUP number to a unit, do the following:
1. Point the remote control transmitter at the remote receiver and press the
GROUP key.
2. Press the digit corresponding to the number of the Group
3
.
This sets and saves the group number.
1 The group 11 machines are protocol 2000 switchers that have only one output, so that the output is preset to 1 and you only
have to press the input number digit on the selector buttons
2 The machine number set up on the unit (for example, via the DIP-switches)
3 According to the specifications in Table 3