38
MV-6 - Default Communication Parameters
9
Default Communication Parameters
RS-232
Protocol 3000
Baud Rate:
115200
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format:
ASCII
Example (Output 1 to Input 2):
#V 2>1CR
Ethernet
To reset the IP settings to the factory reset values, power cycle the
device while holding in the Factory Reset button, located on the rear
panel of the unit
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
TCP Port #: 5000
5000
UDP Port #: 50000
50000
Maximum UDP Ports:
10
Maximum TCP Ports:
4
Содержание MV-6
Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MV 6 3G HD SDI Multiviewer P N 2900 000737 Rev 11...
Страница 2: ......
Страница 46: ...42 MV 6 Kramer Protocol 3000 Syntax 10 7 Maximum String Length 64 characters...
Страница 73: ...MV 6 Parameters 69 12 8 Font Size Number Value 0 Small 1 Medium 2 Large...
Страница 74: ......