MV-6 - Operating the MV-6 Locally
21
6.9.3
Status Sub-Menu
The parameters in the Status Sub-Menu display the input states.
Parameter
Description
Values
INPUTS >
Displays the input states
IN 1 unlocked, IN 2 unlocked,
IN 3 unlocked, IN 4 unlocked,
IN 5 unlocked, IN 6 unlocked
GENLOCK unlocked
Displays the Genlock state
6.9.4
Comm Settings Sub-Menu
The parameters in the Comm Settings Sub-Menu set the network IP and serial
communications values.
Parameter
Description
Options
NETWORK
IP address
Sets the IP network
address
All valid IP addresses
Default
—192.168.001.039
IP mask
Sets the IP network
mask
All valid subnets
Default
—255.255.000.000
IP gateway
Sets the IP gateway
address
All valid gateway addresses
Default
—000.000.000.000
IP port
Sets the IP port number
All valid TCP ports
Default
—05000
RS-232
Baud
Displays the baud rate
115200
Parity
Displays the parity
setting
none
6.9.5
User Presets Sub-Menu
The options in the User Presets Sub-Menu save and recall the preset
configuration memories (see
Parameter
Description
Options
SAVE
Saves the current screen layout as a
user defined layout
USER PRESET 1, USER
PRESET 2
Default
—USER PRESET 1
LOAD
Loads the selected user defined
screen layout
USER PRESET 1, USER
PRESET 2 Default
—USER
PRESET 1