Step 3: Install KC-BRAINware-50
To rack mount the machine, attach both rack ears
(by removing the screws from each side of the
machine and replacing those screws through the
rack ears) or place the machine on a table.
•
Ensure that the environment (e.g., maximum ambient temperature &
air flow) is compatible for the device.
•
Avoid uneven mechanical loading.
•
Appropriate consideration of equipment nameplate ratings should be
used for avoiding overloading of the circuits.
•
Reliable earthing of rack-mounted equipment should be maintained.
Step 4: Connect the inputs and outputs
Always switch OFF the power on each device before connecting it to your
KC-BRAINware-50
. For best results, we
recommend that you always use Kramer high-performance cables to connect AV equipment to
KC-BRAINware-50
.
Connecting Keyboard, Mouse, and Display are optional. SSH has been enabled by default and is the recommended process for
configuring
KC-BRAINware-50
.
For optimum range and performance use the recommended Kramer cables available at
www.kramerav.com/product/KC-BRAINware-50
Using third-party cables may cause damage!
Step 5: Connect the power
Connect the power cord to
KC-BRAINware-50
and plug it into the mains electricity.
Safety Instructions (See
for updated safety information)
Caution:
•
For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual.
•
There are no operator serviceable parts inside the unit.
Warning:
•
Use only the power cord that is supplied with the unit.
•
Disconnect the power and unplug the unit from the wall before installing.
•
Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only.
•
To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.
Step 6: Set up KC-BRAINware-50
Knowledge of IP networking is required to perform the following procedure. Inaccurate IP calculation could damage your IP
network when you start
KC-BRAINware-50
.
1. Connect to
KC-BRAINware-50
using one of the following two methods:
▪
Connect via SSH kramer@IPofHardware and use the password: KC_Brainware.
▪
Connect a mouse, keyboard, and monitor directly to
KC-BRAINware-50
.
2. Identify the gateway and subnet of the network to which
KC-BRAINware-50
is connected.
You may need to contact your IT manager to obtain this information.
3. Connect to the
KC-BRAINware-50
terminal and run the following command to configure a part of the subnet as the
range of addresses for all 50 Brains:
kramer config set docker.brain.network.ip_range=<your starting address>/26
for example:
kramer config set docker.brain.network.ip_range=192.168.110.192/26
4. Run the following commands to update all Brains:
kramer docker update brain
After completion of the update, all Brains start and are available on the customer network.