Technical Specifications
15
7.4.2.3 Selecting
a
Process
To select a Process
1
, do the following:
•
Point the remote control transmitter at the remote receiver and press the
keys 5 and then 3 to cycle between the 6 process LEDs
7.4.2.4
Increasing the Process level
To increase the Process level, do the following:
•
Point the remote control transmitter at the remote receiver and press the
keys 5 and then 5 until the increase in the level is satisfactory
7.4.2.5
Decreasing the Process level
To decrease the Process level, do the following:
•
Point the remote control transmitter at the remote receiver. Press the keys
5 and then 4 until the decrease in the level is satisfactory
7.5 Controlling an Expanded Series 16x16 Matrix Switcher
You can control an expanded series 16x16 matrix switcher, using the IR-1
and/or IR-1-01. For example, when using 2 VS-1616V units to form a 32x16
switcher
1
, set both VS-1616V units as MACHINE # 1
2
. Using the setup
commands, on the first VS-1616V unit, set the IR REMOTE control to ON,
and on the second VS-1616V unit, set the IR REMOTE control to OFF
3
.
When a switcher has no built-in front panel remote receiver, for example,
when using 3 VS-1604 units, set each VS-1604 unit as MACHINE # 1 and
connect an external remote receiver to the first VS-1604 unit only.
8 Technical
Specifications
Table 3 lists the technical specifications:
Table 3: Technical Specifications
4
of the IR-1 and the IR-1-01
Remote Control Transmitter (IR-1 / IR-1-01)
External Remote Receiver
Dimensions:
6 cm (W) x 3 cm (D) x 17 cm (H)
8.5 cm (W) x 8.5 cm (D) x 9.5 cm (H)
Power
Source:
AA size regular 1.5V alkaline battery
Remote current: 21 mA
Stand By: 5 micro A
Power adapter (12V DC Input)
28 mA maximum
Accessories:
Battery
Attached RS-232 Cable and connector
Power adapter
1 See the VS-1616V user manual, section 6.3.1 on page 12
2 As Figure 9 illustrates on page 13 of the VS-1616V user manual
3 See the VS-1616V user manual, section 8.10 on page 51
4 Specifications are subject to change without notice