RC-76R/RC-78R - Connecting the RC-76R/RC-78R 

 

 

Connect the A (+) pin of the device to the 

A

 pin on the RS-485 terminal block 

of the 

RC-76R/RC-78R

 

 

Connect the B (-) pin of the device to the 

B

 pin on the RS-485 terminal block of 

the 

RC-76R/RC-78R

 

 

Connect the G pin of the device to the 

GND

 pin on the RS-485 terminal block 

of the 

RC-76R/RC-78R 

 

If your device is the first or last device on the line, slide the RS-485 termination 
switch up otherwise make sure it is set to down (see 

Figure 1

). 

4.3 

Connecting the Ethernet Port 

The Ethernet connection of the 

RC-76R/RC-78R 

lets you perform all control 

functions of the 

RC-76R/RC-78R

 over the Internet using a PC running the Kramer 

Site-CTRL control program to control AV devices.  

To connect the 

RC-76R/RC-78R

 to a network: 

1.  Connect the Ethernet port of the 

RC-76R/RC-78R

 to the Ethernet port on a 

network hub or network router, via a straight cable with RJ-45 connectors.  

2.  At the other end, connect the Internet to a PC running 

Site-CTRL

3.  After connecting the Ethernet port, you have to install and configure it. For 

detailed instructions on how to install and configure your Ethernet port, see 
the 

K-Config Software Guide. 

 

 

 

 

 

 

 

 

 

 

 

Содержание 2900-300253

Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL RC 76R RC 78R Room Controllers P N 2900 300253 Rev 5...

Страница 2: ......

Страница 3: ...ding the RC 76R RC 78R 11 5 Operating the RC 76R RC 78R 13 6 Front Panel Button Caps and Labels 14 6 1 Installing the Front Panel Button Caps and Labels 17 7 Technical Specifications 19 Figures Figure...

Страница 4: ...1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Co...

Страница 5: ...lity connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight b...

Страница 6: ...ng 2 3 Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it...

Страница 7: ...nfig configuration software 1 general purpose I O port that can be configured by K Config as a digital input digital output or analog input for interfacing with a variety of devices such as sensors sw...

Страница 8: ...RC 76R RC 78R Overview 5 3 1 Defining the RC 76R RC 78R Room Controllers This section defines the RC 76R RC 78R Figure 1 RC 76R RC 78R Room Controllers US D Size...

Страница 9: ...ure Function 1 6 8 Configurable Buttons Function is programmed by the K Config Configuration software 2 USB Connector Connect to a computer for firmware upgrade or for uploading the configuration file...

Страница 10: ...ect it again while pressing the Reset button The unit powers up and loads its memory with the factory default definitions and erases all stored preset 12 RS 232 2 Terminal Block Connector Connects to...

Страница 11: ...R outputs as follows Connect an IR emitter to IR OUTPUT 1 and attach the emitter to the DVD player 1 Connect an IR emitter to IR OUTPUT 2 and attach the emitter to the DVD player 2 2 Connect the RS 23...

Страница 12: ...them to the RC 76R RC 78R via their RS 232 connection To connect a device to the RC 76R RC 78R via RS 232 Using a straight cable connect pin 2 to TX pin 3 to RX and pin 5 to GND on the RS 232 termina...

Страница 13: ...1 4 3 Connecting the Ethernet Port The Ethernet connection of the RC 76R RC 78R lets you perform all control functions of the RC 76R RC 78R over the Internet using a PC running the Kramer Site CTRL c...

Страница 14: ...ation switch up otherwise make sure it is set to down see Figure 1 4 5 Grounding the RC 76R RC 78R The grounding screw is used to earth the chassis of the unit to the building ground preventing static...

Страница 15: ...point wire a green yellow AWG 18 0 82mm2 wire crimped with a proper hand tool is recommended 2 Insert the M3x6 screw through the toothed lock washers and the tongue terminal in the order shown above...

Страница 16: ...These are configured using the K Config software For instructions on using the software see the K Config Software Guide A PC running Site CTRL control software To operate your device using Site CTRL...

Страница 17: ...Caps and Labels 6 Front Panel Button Caps and Labels The RC 76R RC 78R are supplied with a button label sheet and 6 8 clear button caps to house the labels The label size 8 8mm x 8 8mm Figure 6 illus...

Страница 18: ...RC 76R RC 78R Front Panel Button Caps and Labels 15...

Страница 19: ...16 RC 76R RC 78R Front Panel Button Caps and Labels Figure 6 Sample Button Label Sheet...

Страница 20: ...et 2 Unscrew the design frame from the device Put the frame and screws aside 3 To access the buttons remove the two mounting plate screws see Figure 7 and remove the mounting plate Put the plate and s...

Страница 21: ...el 6 Retaining the orientation return each cap to its correct button Figure 9 Replacing the Button Cap 7 Repeat for all caps 8 Replace the mounting plate and screw it into place with its mounting scre...

Страница 22: ...255 255 0 0 Gateway 0 0 0 0 POWER CONSUMPTION 12V DC 260mA OPERATING TEMPERATURE 0 to 40 C 32 to 104 F STORAGE TEMPERATURE 40 to 70 C 40 to 158 F HUMIDITY 10 to 90 RHL non condensing DIMENSIONS 7 9cm...

Страница 23: ...20 RC 76R RC 78R Technical Specifications...

Страница 24: ...n on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found P N 2900 300253 Rev 5 SAFETY WARNING Disconnect the unit from the power supply bef...

Отзывы: