SLD/DLD/PLD AIR COOLED CONDENSING UNITS 

10 

 

TABLE 2A 

SLD CONDENSING UNIT REFRIGERANT CHARGE - POUNDS 

 

 

Above   

Below  

Model 

Refrigerant 

 70 F 

50 F 

30 F 

10 F 

0 F 

-20 F 

SLD 0100  H2 

R-22 

29.1 

39.8 

43.6 

45.9 

46.8 

48.4 

SLD 0150  H2 

R-22 

31.6 

37.3 

44.8 

49.0 

50.6 

53.1 

SLD 0200  H2 

R-22 

31.6 

37.3 

44.8 

49.0 

50.6 

53.1 

SLD 0250  H2 

R-22 

42.4 

50.7 

61.9 

68.2 

70.5 

74.2 

SLD 0300  H2 

R-22 

53.2 

64.2 

79.0 

87.4 

90.4 

95.3 

SLD 0350  H2 

R-22 

55.7 

58.6 

71.9 

84.0 

88.5 

95.4 

SLD 0400  H2 

R-22 

72.5 

76.0 

89.6 

101.9 

106.6 

113.7 

SLD 0500  H2 

R-22 

80.6 

97.0 

119.3 

131.8 

136.4 

143.7 

SLD 0600  H2 

R-22 

97.1 

101.8 

120.0 

136.4 

142.6 

152.2 

SLD 0101  H2 

R-22 

31.6 

42.4 

48.3 

51.6 

53.0 

55.5 

SLD 0151  H2 

R-22 

42.4 

58.4 

67.1 

72.1 

74.1 

77.8 

SLD 0201  H2 

R-22 

42.4 

58.4 

67.1 

72.1 

74.1 

77.8 

SLD 0251  H2 

R-22 

42.3 

48.0 

60.6 

67.1 

69.5 

73.4 

SLD 0301  H2 

R-22 

55.7 

63.9 

82.7 

92.4 

95.9 

101.7 

SLD 0351  H2 

R-22 

80.4 

91.5 

116.6 

129.7 

134.5 

142.2 

SLD 0401  H2 

R-22 

91.2 

132.9 

155.9 

168.7 

173.8 

183.5 

SLD 0501  H2 

R-22 

112.9 

129.4 

166.9 

186.4 

193.5 

205.0 

SLD 0601  H2 

R-22 

137.0 

158.4 

208.2 

234.0 

243.3 

258.4 

SLD 0220  L2 

R-22 

31.6 

47.5 

51.8 

54.1 

55.2 

57.1 

SLD 0270  L2 

R-22 

36.9 

60.3 

66.6 

70.0 

71.5 

74.1 

SLD 0300  L2 

R-22 

36.9 

60.3 

66.6 

70.0 

71.5 

74.1 

SLD 151  L2 

R-22 

36.9 

60.3 

66.6 

70.0 

71.5 

74.1 

SLD 0221  L2 

R-22 

36.9 

60.3 

66.6 

70.0 

71.5 

74.1 

SLD 0271  L2 

R-22 

36.8 

53.8 

62.1 

54.9 

68.4 

71.4 

SLD 0301  L2 

R-22 

50.2 

75.6 

87.9 

77.0 

97.3 

101.6 

SLD 0150  M4 

R-404A 

27.9 

33.4 

40.2 

44.2 

45.7 

48.1 

SLD 0200  M4 

R-404A 

27.9 

33.4 

40.2 

44.2 

45.7 

48.1 

SLD 0250  M4 

R-404A 

37.4 

45.4 

55.6 

61.5 

63.6 

67.1 

SLD 0300  M4 

R-404A 

46.9 

57.4 

70.9 

78.7 

81.6 

86.1 

SLD 0350  M4 

R-404A 

42.2 

45.0 

53.3 

60.9 

63.8 

68.2 

SLD 0400  M4 

R-404A 

70.8 

75.7 

91.9 

106.8 

112.5 

121.0 

SLD 0151  M4 

R-404A 

37.4 

52.1 

60.2 

64.9 

66.8 

70.3 

SLD 0201  M4 

R-404A 

37.4 

52.1 

60.2 

64.9 

66.8 

70.3 

SLD 0251  M4 

R-404A 

49.0 

57.1 

74.1 

83.2 

86.5 

91.8 

SLD 0301  M4 

R-404A 

63.9 

72.9 

90.2 

99.6 

103.1 

108.7 

SLD 0351  M4 

R-404A 

71.0 

100.2 

116.3 

125.7 

129.4 

136.4 

SLD 0401  M4 

R-404A 

95.1 

134.1 

155.6 

168.1 

173.1 

182.4 

SLD 0220  L4 

R-404A 

29.3 

37.9 

43.3 

46.6 

47.9 

50.3 

SLD 0270  L4 

R-404A 

39.5 

52.1 

60.2 

64.9 

66.8 

70.3 

SLD 0300  L4 

R-404A 

44.8 

61.2 

71.8 

77.9 

80.4 

84.9 

SLD 0221  L4 

R-404A 

39.5 

58.9 

64.8 

68.3 

69.8 

72.4 

SLD 0271  L4 

R-404A 

39.4 

53.1 

60.9 

54.9 

67.1 

70.0 

SLD 0301  L4 

R-404A 

52.2 

72.4 

83.9 

74.7 

93.0 

97.1 

 

Содержание DLD Series

Страница 1: ...ATION MANUAL INSTALLING INSTRUCTIONS SLD DLD PLD AIR COOLED CONDENSING UNITS SLD SERIES COND UNITS R 22 R 404A R 507 10 60 HP DLD SERIES COND UNITS R 22 R 404A R 507 7 50 HP CIRCUIT PLD SERIES COND UNITS R 22 R 404A R 507 14 100 HP ...

Страница 2: ...I System Evacuation 5 IV Electrical 5 V Charging the System 5 VI Operation Checkout 5 VII Features and Controls 6 VIII Normal Maintenance 7 TABLES Table 1 Recommended Line Sizes 8 9 Table 2 Condensing Unit Refrigerant Charge 10 11 12 Table 3 Low Pressure Control Settings 13 Table 4 Fan Cycling Control Settings 13 ...

Страница 3: ... 460 3 60 P 575 3 60 Levitor Condenser U 380 3 50 Compressor Manufacture Refrigerant B Bitzer Semi Hermetic 2 R22 C Carlyle Semi Hermetic 4 R404A D Copeland Discus 7 R507 I Ingersoll Rand Semi Hermetic V Copeland Screw Temperature H High Total HP M Medium 0100 10 HP w standard comp L Low 0101 10 HP w oversized comp 0700 2 35 HP w standard comp 0701 2 35 HP w oversized comp Large Condensing Unit Mo...

Страница 4: ...air or restricting the free entry of air into the coil will result in reduced capacity and highpower consumption Take care to reduce such negative operation effects by providing for unrestricted free air flow into and from the unit At most the unit should not be positioned so as to have no more than one of its sides positioned close to a vertical building side or wall At that point this should be ...

Страница 5: ... free rag before fabrication into the system Soft solders should be avoided wherever possible as in most cases they require the use of a flux Most of the low temperature solder flux consists of heavy wax type materials which if allowed to enter the system cause excessive service problems in the form of wax at expansion valves which looks like moisture but cannot be removed by the average dryer cor...

Страница 6: ...e system When initially charging a system that is in a vacuum liquid refrigerant can be directly added into the receiver until the system pressure equalizes with pressure in the refrigerant cylinder Start the system and finish charging until the sight glass is clear Outdoor condensing units are furnished with a condenser flooding type of head pressure control valve for cold weather operation This ...

Страница 7: ...ommended to pump the oil directly into the compressor against suction pressure Refrigerant oil should be purchased in sealed containers and should not be left open to atmosphere Exposure to air and moisture for extended periods will result in contamination of the oil and cause harmful reactions in the compressor Do not transfer oil from one container to another 2 HIGH AND LOW PRESSURE CONTROLS SLD...

Страница 8: ... of the fan rotation 6 CONDENSER FAN CYCLING Pressure switches are included to cycle all but the first condenser fan s in response to head pressure See Table 4 for suggested pressure settings used on all multiple condenser fan systems 7 LOW AMBIENT FLOODING CONTROLS ARE STANDARD Condenser Liquid Flooding utilizes a field adjustable 100 to 225 psig condensate holdback valve Head pressure control va...

Страница 9: ... 1 8 1 2 5 8 5 8 5 8 120 000 1 3 8 1 3 8 1 5 8 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 5 8 5 8 5 8 7 8 150 000 1 3 8 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 2 1 8 2 5 8 5 8 7 8 7 8 7 8 180 000 1 3 8 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 2 5 8 2 5 8 5 8 7 8 7 8 7 8 210 000 1 5 8 2 1 8 2 1 8 2 1 8 2 1 8 2 5 8 2 5 8 2 5 8 5 8 7 8 7 8 7 8 240 000 1 5 8 2 1 8 2 1 8 2 1 8 2 1 8 2 5 8 2 5 8 2 5 8 5 8 7 8 7 8 7 8 300 000 2 1 8 2 1 8...

Страница 10: ...5 8 5 8 5 8 5 8 5 8 84 000 1 1 8 1 3 8 1 5 8 1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 5 8 5 8 5 8 5 8 90 000 1 3 8 1 3 8 1 5 8 1 5 8 1 5 8 1 5 8 2 1 8 2 1 8 5 8 5 8 5 8 7 8 120 000 1 3 8 1 5 8 1 5 8 2 1 8 1 5 8 2 1 8 2 1 8 2 1 8 5 8 5 8 7 8 7 8 150 000 1 5 8 1 5 8 2 1 8 2 1 8 2 1 8 2 1 8 2 1 8 2 5 8 5 8 7 8 7 8 7 8 180 000 1 5 8 2 1 8 2 1 8 2 1 8 2 1 8 2 1 8 2 5 8 2 5 8 7 8 7 8 7 8 7 8 210 000 1 5 8 2 1 8 2 ...

Страница 11: ... 258 4 SLD 0220 L2 R 22 31 6 47 5 51 8 54 1 55 2 57 1 SLD 0270 L2 R 22 36 9 60 3 66 6 70 0 71 5 74 1 SLD 0300 L2 R 22 36 9 60 3 66 6 70 0 71 5 74 1 SLD 151 L2 R 22 36 9 60 3 66 6 70 0 71 5 74 1 SLD 0221 L2 R 22 36 9 60 3 66 6 70 0 71 5 74 1 SLD 0271 L2 R 22 36 8 53 8 62 1 54 9 68 4 71 4 SLD 0301 L2 R 22 50 2 75 6 87 9 77 0 97 3 101 6 SLD 0150 M4 R 404A 27 9 33 4 40 2 44 2 45 7 48 1 SLD 0200 M4 R 4...

Страница 12: ...0 6 67 1 69 5 73 4 DLD 0601 H2 R 22 55 7 63 9 82 7 92 4 95 9 101 7 DLD 0701 H2 R 22 80 4 91 5 116 6 129 7 134 5 142 2 DLD 0801 H2 R 22 90 8 95 9 126 1 145 9 152 3 164 1 DLD 1001 H2 R 22 117 9 122 3 147 4 176 9 1067 7 203 1 DLD 1201 H2 R 22 136 6 141 6 157 9 198 1 209 5 231 5 DLD 0440 L2 R 22 23 9 36 5 42 7 37 2 47 3 49 4 DLD 0540 L2 R 22 27 8 44 5 52 6 45 3 58 7 61 5 DLD 0600 L2 R 22 36 9 60 3 66 ...

Страница 13: ...71 1 91 3 95 5 PLD 0540 L2 R 22 52 6 85 9 102 1 87 3 114 2 119 7 PLD 0600 L2 R 22 58 3 104 5 116 8 123 3 126 2 131 2 PLD 0441 L2 R 22 52 6 85 9 102 1 87 3 114 2 119 7 PLD 0541 L2 R 22 63 4 124 5 140 6 149 1 152 8 159 1 PLD 0601 L2 R 22 73 9 123 6 147 9 125 6 165 9 174 1 PLD 0500 M4 R 404A 70 8 75 7 91 9 106 8 112 5 121 0 PLD 0600 M4 R 404A 95 1 116 1 143 2 158 8 164 6 173 7 PLD 0700 M4 R 404A 85 7...

Страница 14: ...ture at the condensing unit or the box design temperature whichever is lower Example 1 30 F minimum ambient 20 F freezer Use 20 F value from Table Example 2 10 F minimum ambient 35 F cooler Use 10 F value from Table TABLE 3B HIGH PRESSURE CONTROL SETTINGS R 22 400 Psig R 404A R 507 400 Psig TABLE 4 FAN CYCLING CONTROL SETTINGS Number of Fans Control Cut In Settings PSIG Single Row Double Row Refri...

Отзывы: