Safety Information
!
Read First
!
Understand and follow operating instructions carefully.
WARNING
!
Identifies hazardous conditions and actions that could cause
BODILY HARM or DEATH.
WARNING
!
•
When using test leads or probes, keep your fingers behind the
finger guards.
•
Remove test lead from Meter before opening the battery door or
meter case.
•
Use the Meter only as specified in this manual or the protection
by the Meter might be impaired.
•
Always use proper terminals, switch position, and range for
measurements.
•
Verify the Meter’s operation by measuring a known voltage.
If in doubt, have the Meter serviced.
•
Do not apply more than the rated voltage, as marked on Meter,
between terminals or between any terminal and earth ground.
•
Only replace the blown fuse with the proper rating as specified
in this manual.
•
Use caution with voltages above 30 Vac rms, 42 Vac peak,or 60
Vdc. These voltages pose a shock hazard.
•
To avoid false readings that can lead to electric shock and
injury, replace battery as soon as low battery indicator.
•
Disconnect circuit power and discharge all high-voltage
capaci-tors before testing resistance, continuity, diodes, or
capacitance.
•
Do not use Meter around explosive gas or vapor.
•
To reduce the risk of fire or electric shock do not expose this
product to rain or moisture.
CAUTION
!
Identifies conditions and actions that could DAMAGE the meter or
equipment under test.