Kozy-World KWN215 Скачать руководство пользователя страница 9

9

INSTALLATION

CONNECTING TO GAS SUPPLY

       WARNING:  A  qualified
service  person  must  connect
heater  to  gas  supply. Follow  all
local  codes.

           WARNING:  This  appliance
requires  a  3/8

"

  NPT  (National

Pipe  Thread)  inlet  connection
to  the  pressure  regulator.

          WARNING:  Never  connect
heater  to  private (non-utility)  gas
well. This  gas  is  commonly
known as  well-head  gas.

IMPORTANT:  Check  your  gas  line
pressure  before  connecting  heater
to  gas  line. Gas  line  pressure  must
be no greater than 10.5  inches of
water.  If  gas  line pressure  is  higher,
heater  regulator  damage  could
occur.

       CAUTION:  Use  only  new,
b l a c k   i r o n     o r   s t e e l     p i p e .
Internally-tinned  copper  tubing
may  be  used  in  certain  areas.
Check   your  local  codes.  Use pipe
of  large  enough   diameter to
allow  proper  gas  volume  to heater.
I f       p i p e       i s       t o o       s m a l l ,
undue  loss  of pressure  will
occur.  

Typical Inlet Pipe Diameters
All models up to 20,000 BTU’s use
3/8’’ or greater pipe;
All models 25,000 BTU’s and higher,
use 1/2” or greater pipe.

Installation   must   include  an
equipment   shutoff   valve,   union,
and  plugged  1/8

"

 NPT  tap.  Locate

NPT tap within  reach  for  test  gauge
hook   up.   NPT  tap  must  be
upstream  from  heater  (see  Figure
13).

*A  CSA/AGA  design-certified  equipment  shutoff  valve  with  1/8

"

  NPT  tap  is

an  acceptable  alternative  to  test  gauge  connection.  Purchase the  optional
C S A / A G A    d e s i g n - c e r t i f i e d     e q u i p m e n t     s h u t o f f     v a l v e     f r o m
your  dealer.  See  Accessories,  page 17.

IMPORTANT:  Install  an  equipment
shutoff  valve  in  an  accessible
location. The  equipment  shutoff
valve   is  for  turning  on  or  shutting
off  the  gas  to  the  appliance.

Apply  pipe  joint  sealant  lightly  to
male  threads.  This  will  prevent
excess  sealant  from  going  into
pipe.  Excess  sealant  in  pipe  could
result  in  clogged  heater  valves.

Install  sediment  trap  in  supply  line
as  shown  in  Figure 13.  Locate
sediment  trap  where  it  is  within
r e a c h       f o r     c l e a n i n g .     L o c a t e
sediment    trap   where   trapped
matter  is  not  likely  to  freeze.  A
sediment   trap  traps  moisture  and
contaminants.  This   keeps  them
from  going  into  heater  controls.  If
sediment  trap  is  not  installed    or  is
i n s t a l l e d     w r o n g ,     h e a t e r     m a y
not  run  properly.

IMPORTANT

:    Hold   pressure

r e g u l a t o r     w i t h     w r e n c h     w h e n
connecting it to gas piping and/or
fittings.

           CAUTION:   Use   pipe   joint
sealant  that  is  resistant  to
natural  gas.

Figure 13 -Gas  Connection

Содержание KWN215

Страница 1: ...or use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Save...

Страница 2: ...face of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shut down Allow surface t...

Страница 3: ...the greatest heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel...

Страница 4: ...ation air by one of the methods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may pr...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...t union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur...

Страница 7: ...en down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their c e n t...

Страница 8: ...ace mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firm...

Страница 9: ...1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable a...

Страница 10: ...r 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles...

Страница 11: ...ting pilot again 8 Turn control knob counterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO n THERMOSTATn CONTROL OPERATION The the...

Страница 12: ...ightly press in control turn control knob clockwise to the PILOT position Figure 18 Control Knob In The OFF Position Figure 19 Pilot 1 STOP Read the safety information on the side of heater 2 Make sur...

Страница 13: ...pilot flame comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if com pressed air is not available Figur...

Страница 14: ...nt shutoff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This prob...

Страница 15: ...expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning an...

Страница 16: ...pors from paint hair spray glues etc See IMPORTANT statement above 2 G a s l e a k S e e W a r n i n g statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is p...

Страница 17: ...number 814 643 2299 ACCESSORIES Purchase these heater accesso ries from your local dealer If they can not supply these accessories contact KOZY WORLD for information You can also write to the address...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS KWN217 KWN317 ODS Pilot Assembly...

Страница 19: ...er Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermosstat Valve Base Assembly Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembl...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS KWN215 KWN315 ODS Pllot Assembly...

Страница 21: ...ew Control valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly Medi...

Отзывы: