Kozy-World KWN215 Скачать руководство пользователя страница 7

7

INSTALLATION

Figure 8 - Mounting  Bracket
Clearances

Figure 7 - Removing  Lower Front
Panel  Of  Heater

Figure  4 -Mounting  Clearance as
Viewed  From  Font  Of  Heater

Figure 5 - Moving Thermostat
Sensing Bulb

      IMPORTANT:   Vent-free
heaters  add  moisture  to   the
air.  Although  this  is  beneficial,
installing  heater  in  rooms
without  enough  ventilation  air
may   cause  mildew  to    form
from  too  much  moisture.  See

Fresh  Air  for Combustion and
Ventilation

,  pages  4 and 5.

INSTALLING THERMOSTAT
SENSING BULB
For T-Stat  Models  Only
1. Pull out the sensing  bulb  from the
    two  clips  located  in  the  shippng
    position according to the direction
   as shown by the arrow. There is no
    need to take out  the two bulb clips.
2. Take  out  the  bulb  clip  from  the
     hardware package and insert  it into
      the square hole and then insert the
     sensing bulb into the bulb clip (see
     Figure 5).

FASTENING  HEATER  TO  WALL
Mounting  Bracket
The  mounting  bracket  is  located
on   back  panel  of  heater (see
figure 6).  It  has  been  taped  there
for shipping. Remove mounting
bracket  from  back  panel.

Removing  Lower Front  Panel  Of
The Heater
1.  Remove  two  screws  near bottom
     corners  of  lower front  panel
2.  Pull  bottom of  lower front  panel
     forward, then  down (see Figure 7).

Methods For Attaching  Mounting
Bracket  To Wall
Only  use  last  hole  on  each  end
of  mounting  bracket  to  attach
bracket   to  wall. These  two  holes
are  16  inches  apart  from their
c e n t e r s .     A t t a c h     m o u n t i n g
bracket   to  wall  only in one of  two
ways:
1.    Attaching  to  wall  stud
2.    Attaching  to  wall  anchor
Attaching  To  Wall  Stud:    This
method   provides   the   strongest
hold.   Insert    mounting    screws
through    mounting    bracketand
into  wall  studs.

Attaching  to  Wall  Anchor: This
method  allows  you  to attach
mounting  bracket  to  hollow  walls
(wall areas between  studs) or to
solid   walls  (concrete  or  masonry).
Decide   which   method   better
suits  your  needs.  Either  method
will  provide  a  secure   hold  for  the
mounting  bracket.

Marking  Screw  Locations

1.  Tape  mounting  bracket  to  wall
where  heater  will  be  located.
Make  sure  mounting  bracket  is
level.

2.  Mark  screw  locations  on
wall. (see  Figure  8)

Note:

  Only  mark  last  hole  on

each  end  of  mounting  bracket.
Insert  mounting  screws  through
these  holes  only.
3.   Remove  tape and  mounting
bracket  from  wall.

          WARNING:      Maintain
minimum   clearances  shown  in
Figure 8. If  you  can,  provide
greater   clearances   from   floor
and   joining   wall.

Figure  6 -Mounting  Bracket
Location

         WARNING:   Maintain  the
minimum  clearances  shown
i n     F i g u r e   4 .     I f     y o u   c a n ,
provide   greater   clearances   from
floor,   ceiling,  and   joining  wall.

Model  KWN315  KWN317

Model  KWN215  KWN217

Содержание KWN215

Страница 1: ...or use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Save...

Страница 2: ...face of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shut down Allow surface t...

Страница 3: ...the greatest heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel...

Страница 4: ...ation air by one of the methods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may pr...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...t union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur...

Страница 7: ...en down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their c e n t...

Страница 8: ...ace mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firm...

Страница 9: ...1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable a...

Страница 10: ...r 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles...

Страница 11: ...ting pilot again 8 Turn control knob counterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO n THERMOSTATn CONTROL OPERATION The the...

Страница 12: ...ightly press in control turn control knob clockwise to the PILOT position Figure 18 Control Knob In The OFF Position Figure 19 Pilot 1 STOP Read the safety information on the side of heater 2 Make sur...

Страница 13: ...pilot flame comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if com pressed air is not available Figur...

Страница 14: ...nt shutoff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This prob...

Страница 15: ...expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning an...

Страница 16: ...pors from paint hair spray glues etc See IMPORTANT statement above 2 G a s l e a k S e e W a r n i n g statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is p...

Страница 17: ...number 814 643 2299 ACCESSORIES Purchase these heater accesso ries from your local dealer If they can not supply these accessories contact KOZY WORLD for information You can also write to the address...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS KWN217 KWN317 ODS Pilot Assembly...

Страница 19: ...er Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermosstat Valve Base Assembly Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembl...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS KWN215 KWN315 ODS Pllot Assembly...

Страница 21: ...ew Control valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly Medi...

Отзывы: