Kozy-World KWN215 Скачать руководство пользователя страница 11

1 1

Figure 16 - Control  Knob  In  The
OFF  Position

Figure 17 - Pilot

OPERATING   YOUR   HEATER

THERMOSTAT  MODELS

n

LIGHTING

n

INSTRUCTIONS

1 .   S T O P !     R e a d       t h e     s a f e t y
    information  on  the  side of
      heater.
2.  Check  that  gas  supply  to
       heater  is  on.
3.  Push  in  gas  control  knob
       slightly  and  turn  clockwise
      to the OFF position.

NOTE

:   knob  cannot  be  turned from

“PILOT”  to  “OFF”  unless knob  is
p u s h e d     i n     s l i g h t l y .   D o     n o t
force.

4.   Wait five (5) minutes  to  clear
      out   any   air. Then   smell  for
       gas,  including  near  the  floor.
        If      you      smell     gas,    STOP!
       Follow   “B”     in     the     safety
        information  on  the  side of  the
       heater.  If   you   do   not   smell
       gas,  go  to  the  next  step.
5.    Push     in    gas   control   knob
        slightly                  and                 turn
       counterclockwise   

       to

      “PILOT/IGN”  and  depress  for
        five(5) seconds

NOTE

:   The  first  time  that  the

h e a t e r       i s     o p e r a t e d     a f t e r
connecting  the  gas  supply ,  the
control  knob  should  be  depressed
for  about  thirty (30) seconds.  This
will   allow  air  to  bleed   from  the  gas
system.

6.    With  control  knob  pressed  in,
       push  down  and   release   the
     ignitor button. This  will  light
        pilot.  If   needed,  keep    pressing
       ignitor  button  until pilot  lights.

NOTE

:  If  pilot  does  not  stay  lit,

refer  to  

Troubleshooting

,  pages

14  through  16.   Also  contact  a
qualified  service person  or  gas
supplier   for   repairs.  Until   repairs
are   made,   light   pilot   with   match.
To  light  pilot  with  match, see

Manual   Lighting   Procedure.

7.   Keep  control  knob  pressed  in
     for  thirty  (30)  seconds  after
       lighting       pilot.         After       30
       seconds,  release  control  knob.

If   control   knob  does   not   pop

     up  when  released,  contact  a
      qualified     service    person    or
       gas  supplier  for  repairs.

NOTE

:   If  pilot  goes  out,  repeat

steps 3 through 7. Wait one (1)
minute  before  lighting  pilot  again

8.   Turn             control            knob
     counterclockwise    

       to

      desired    heating    Level.   The
      main  burner  should  light.  Set
      control  knob  to  any  heat  level
       between  HI  and  LO.

n

THERMOSTAT

n

CONTROL

OPERATION

The  thermostatic  control  used  on
these  models  differs from  standard
thermostats.  Standard   thermostats
simply  turn  on  and  off  the  burner.
The  thermostat  used  on   this heater
senses  the  room   temperature.  The
thermostat     adjusts     the    amount
of    gas    flow     to     the       burner.

  TO TURN OFF     

n

GAS TO APPLIANCE

Shutting  Off  Heater
1.   Turn  control  knob  clockwise

         

  to  the  OFF  position.

2.     Turn  off  all   electric   power   to
       the  appliance  if  service  is  to
        be  performed.

SHUTTING OFF BURNER ONLY
(PILOT STAYS LIT)

Tu r n   c o n t r o l   k n o b   c l o c k w i s e  
to  the  PILOT/IGN  position.

n

MANUAL LIGHTING

n

PROCEDURE

1.    Remove  lower   front   panel (see
        Figure 7 page 7).
2.   Follow   steps   1   through  5
        under 

Lighting Instructions

.

3.     With   control   knob   pressed  in,
        strike    match.    Hold   match    to
        pilot until pilot lights.
4.     Keep  control  knob  pressed  in
      for 30  seconds  after lighting
        pilot.  After  30  seconds, release
      control   knob.  Follow   step  8
        under  

Lighting  Instructions.

5.     Replace   lower  front   panel.

This  increases  or  decreases   the
burner  flame height.  At  times  the  room
may exceed  the  set temperature.  If  so,
the  burner  will  shut  off.  The  burner
will  cycle  back  on  when room  tem-
perature  drops   below  the set
temperature. The      control knob  can
be  set  to  any  heat  level between  HI
and LO. Selecting  the HI  setting  will
cause  the  burner  to remain  fully  on
without modulating  down  in  most cases.

NOTE

:    the   thermostat sensing        bulb

measures  the  temperature  of air  near
the  heater  cabinet. This may  not  al-
ways   agree   with   room  temperature
(depending  on  housing  construction.
installation  location,  room  size,      open
air  temperatures, etc.). frequent  use  of
your  heater  will   let  you  determine

  your  own  comfort  levels.

Содержание KWN215

Страница 1: ...or use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Save...

Страница 2: ...face of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shut down Allow surface t...

Страница 3: ...the greatest heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel...

Страница 4: ...ation air by one of the methods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may pr...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...t union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur...

Страница 7: ...en down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their c e n t...

Страница 8: ...ace mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firm...

Страница 9: ...1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable a...

Страница 10: ...r 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles...

Страница 11: ...ting pilot again 8 Turn control knob counterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO n THERMOSTATn CONTROL OPERATION The the...

Страница 12: ...ightly press in control turn control knob clockwise to the PILOT position Figure 18 Control Knob In The OFF Position Figure 19 Pilot 1 STOP Read the safety information on the side of heater 2 Make sur...

Страница 13: ...pilot flame comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if com pressed air is not available Figur...

Страница 14: ...nt shutoff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This prob...

Страница 15: ...expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning an...

Страница 16: ...pors from paint hair spray glues etc See IMPORTANT statement above 2 G a s l e a k S e e W a r n i n g statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is p...

Страница 17: ...number 814 643 2299 ACCESSORIES Purchase these heater accesso ries from your local dealer If they can not supply these accessories contact KOZY WORLD for information You can also write to the address...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS KWN217 KWN317 ODS Pilot Assembly...

Страница 19: ...er Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermosstat Valve Base Assembly Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembl...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS KWN215 KWN315 ODS Pllot Assembly...

Страница 21: ...ew Control valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly Medi...

Отзывы: