VENTILATION  AIR

Ventilation  Air  From  Outdoors
Provide  extra  fresh  air  by  using
ventilation  grills  or  ducts: You  must
provide  two  permanent  openings: one
within  12

"

  of  the  ceiling  and  one  within

12

"

  of  the  floor.

Connect  these  items  directly  to  the
outdoors  or  spaces open to the  outdoors.
These spaces include attics and crawl
spaces. Follow   the

   National  Fuel  Gas

Code  NFPA 54/ANS Z223.1, Section 5.3.
Air  for  Combustion  and  Ventilation

  for

required  size of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings
for  inlet  or  outlet  air  into  attic  if  attic has
a  thermostat-controlled  power  vent.
Heated  air  entering  the  attic  will  activate
the  power  vent.

              NOTICE:   This  heater  is
intended   for  use  as  supplemental
heat. Use   this  heater  along  with
your  primary  heating  system. Do
not  install  this  heater. as your
primary  heat  source. If  you have
a  central  heating  system, you
may  run  system’s  circulating
blower  while  using  heater. This
will   help  circulate the  heat
throughout   the  house.  In  the
event  of  a  power outage,  you can
use  this  heater  as  your primary
heat  source.

        WARNING:   A  qualified
service   person   must  install
heater.  Follow  all  local  codes.

CHECK  GAS TYPE
Use  only natural gas. If your gas
supply is not natural, do not  install
heater. Call  dealer  where you
bought   heater  for  proper  type heater.

INSTALLATION  NEEDS

Before  installing  heater,  make  sure
you have  the  items  listed below.

piping (check  local  codes)

sealant (resistant   to  natural  gas)

equipment   shutoff   valve*

ground  joint  union

test  gauge   connection*

sediment   trap

tee   joint

pipe   wrench

*A   CSA/AGA  design-certified
equip-ment   shutoff   valve  with  1/8

"

NPT   tap   is   an   acceptable
a l t e r n a t i v e       t o     t e s t     g a u g e
connection.  Purchase  the  optional
CSA/AGA    design    certified
equipment   shutoff   valve   from  your

dealer.  See  Accessories,  page  17.

LOCATING  HEATER

This  heater  is  designed  to  be
mounted  on  a  wall.  You  can  locate
heater  on  floor,  away  from  a  wall.
An  optional  floor  mounting  stand is
needed.  Purchase   the   floor
mounting   stand   from   your   dealer.
See   Accessories,   page 17.
For  convenience  and  efficiency,
install  heater

l  

where  there  is  easy  access for

      operation, inspection, and service

 in coldest part of room

An  optional  fan  kit  is  available  from
your   dealer.   See   Accessories,
page 17.  If  planning  to  use  fan,
locate  heater  near  an  electrical
outlet.

INSTALLATION

CAUTION:  If  you  install  the
heater  in  a  home  garage

heater  pilot  and  burner  must

      be  at  least  18  inches  above
        floor.

locate   heater  where  moving

        vehicle  will  not  hit  it.

           CAUTION:   This  heater
creates  warm  air  currents.
These  currents  move  heat
t o   w a l l       s u r f a c e s     n e x t     t o
h e a t e r .   I n s t a l l i n g     h e a t e r
next  to  vinyl  or  cloth  wall
c o v e r i n g s     o r     o p e r a t i n g
heater   where  impurities  (such as
tobacco smoke,  aromatic   candles,
cleaning  fluids, oil or kerosene
lamps,  etc.)  in  the  air  exist  may
discolor   walls.

Figure  3 -Ventilation  Air  from  Outdoors

           WARNING:  Never  install
the  heater

 in a bedroom or bathroom.

 in a recreational vehicle.

where    curtains,    furniture,

      clothing,   or   other   flammable
      objects are less than  36 inches
      from  the  front,  top, or sides  of
      the  heater.

 as  a  fireplace  insert.

 in   high  traffic  areas.

 in   windy  or  drafty  areas.

Содержание KWN215

Страница 1: ...or use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Save...

Страница 2: ...face of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shut down Allow surface t...

Страница 3: ...the greatest heater comfort and may result in lower gas bills LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel...

Страница 4: ...ation air by one of the methods described in the National Fuel Gas Coda ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may pr...

Страница 5: ...n the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent ga...

Страница 6: ...t union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur...

Страница 7: ...en down see Figure 7 Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their c e n t...

Страница 8: ...ace mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firm...

Страница 9: ...1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 13 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable a...

Страница 10: ...r 3 Make sure control knob of heater is in the OFF position 4 Check all joints from equipment shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles...

Страница 11: ...ting pilot again 8 Turn control knob counterclockwise to desired heating Level The main burner should light Set control knob to any heat level between HI and LO n THERMOSTATn CONTROL OPERATION The the...

Страница 12: ...ightly press in control turn control knob clockwise to the PILOT position Figure 18 Control Knob In The OFF Position Figure 19 Pilot 1 STOP Read the safety information on the side of heater 2 Make sur...

Страница 13: ...pilot flame comes out of the pilot assembly see Figure 24 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if com pressed air is not available Figur...

Страница 14: ...nt shutoff valve is not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermo couple This allows thermocouple to cool causing pilot flame to go out This prob...

Страница 15: ...expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning an...

Страница 16: ...pors from paint hair spray glues etc See IMPORTANT statement above 2 G a s l e a k S e e W a r n i n g statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is p...

Страница 17: ...number 814 643 2299 ACCESSORIES Purchase these heater accesso ries from your local dealer If they can not supply these accessories contact KOZY WORLD for information You can also write to the address...

Страница 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS KWN217 KWN317 ODS Pilot Assembly...

Страница 19: ...er Glass Retainer Self Tapping Screw Thermostat Valve Assembly Screws Thermosstat Valve Base Assembly Ignitor Assembly Ignitor Line Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembl...

Страница 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS KWN215 KWN315 ODS Pllot Assembly...

Страница 21: ...ew Control valve Ignitor Line Control Knob Assembly Control Valve Fixed Nut Pressure Regulator Washer Self Locking Screw Main Inlet Tube Assembly ODS Line Assembly Lower Gas Outline Tube Assembly Medi...

Отзывы: