SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot shuts off the heater if there
is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater is equipped with an electronic piezo control system. This system requires one (1) AAA battery (provided).
THERMOSTAT HEAT CONTROL
The control automatically cycles the burner on and off to maintain a desired room temperature. See page 19.
2 GAS OPTIONS CAPABLE
Your heater is equipped to operate on either propane or natural gas. The heater is shipped from the factory ready for connecting
to propane. The heater can easily be changed to natural gas by having your qualified installer follow the instructions on page
15 and the markings on the heater.
State of Massachusetts
: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of
Massachusetts. Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each
purchaser a copy of 527 CMR 30 upon sale of the unit.
In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall be prohibited in bedrooms
and bathrooms.
In the State of Massachusetts the gas cock must be a T-handle type. The State of Massachusetts requires
that a flexible appliance connector cannot exceed three feet in length.
Install and use heater with care. Follow all codes. In the absence of local codes, use the latest edition of The National Fuel Gas
Code, ANSI Z223.1, also known as NFPA 54*.
*Available from:
American National Standard Institute, Inc
National Fire Protection Association, Inc.
1430 Broadway
1 Batterymarch Park
New York, NY 10018
Quincy, MA 02269-9101
This heater is designed for vent-free operation. State and local codes in some areas prohibit the use of vent-free heaters.
LOCAL CODES
PRODUCT FEATURES