THERMOSTATIC CONTROL OPERATION
The thermostatic control used on this model differs from standard thermostats. Standard thermostats simply turn the burner on
and off. The thermostat used on this heater senses the room temperature. At times the room may exceed the set temperature.
If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The
control knob can be set to any comfort level between HIGH (5) and LOW (1).
Note
: The thermostat sensing bulb measures the temperature depending on housing construction.
TO TURN OFF GAS TO APPLIANCE
Shut off heater.
Turn Control Knob clockwise
to the OFF position. Do not force.
MANUAL LIGHTING PROCEDURE
(Match light)
1. Remove screen by lifting and pulling forward.
2. Follow steps 1 through 5 under Lighting Instructions.
3. With control knob in PILOT position, strike match, and
hold near pilot. Press in control knob; pilot should light.
4. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
5. Make sure the heater screen is in place before operating heater.
Fig. 19 - Control Knob Position
Ignitor Control Knob