OPERATION

FOR YOUR SAFETY READ BEFORE LIGHTING 

 

 

WARNING

: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal 

        injury, or loss of life.

 

 

NOTICE

: During initial operation of new heater, burning logs will give off a paper burning smell. Orange flame will also be 

        present. Open a window to vent smell. This will last only a few hours. 

 

CAUTION

: Do not try to adjust heating levels by using the equipment shutoff valve. 

A. This appliance has a pilot which must be lit by the electronic ignitor. When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is 

    heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance. 

• Do not touch any electrical switch; do not use any phone in your building. 

• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

• If you cannot reach your gas supplier, call the fire department. 

C. Use only your hand to push control. Never use tools. If the appliance does not operate, don’t try to repair it. Call a qualified 

     service technician or gas supplier. Forced or attempted repair may result in a fire or explosion. 

D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the 

     appliance and to replace any part of the control system and any gas control, which has been under water.

 

Note

: Please wait one minute after shutting off fireplace to allow the control valve to reset before starting again.

LIGHTING INSTRUCTIONS

Unscrew ignitor cap and install a AAA battery with the + pointing out. Replace cap.
1.   

STOP!

 Read the safety information on page 18.

2.   

Warning

: You must operate this heater with the screen in place. Make sure screen is installed before running heater.

3.   Turn control knob clockwise to the OFF position, see Fig. 19, page 19.
4.   Wait five (5) minutes to clear out any gas. Then smell for gas around heater and near floor. If you smell gas, 

STOP

! Follow 

      "B" in the safety information on Warnings plate. If you don't smell gas, go to the next step.
5.   Turn control knob counterclockwise to the PILOT position. Keep control knob pressed in for five (5) seconds. 

Note

: You may 

      be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 
      30 seconds. This will allow air to bleed from the gas system. If control knob does not pop up when released, contact a 
      qualified service person or gas supplier for repairs.
6.   With control knob pressed in, push down and release ignitor button. This will light pilot.The pilot is attached to the rear of 
      the front burner. If needed, keep pressing ignitor button until pilot lights. 

Note

: If pilot does not stay lit, contact a qualified 

      service person or gas supplier for repairs. Until repairs are made, light pilot with match.

7.   Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. 

Note

: If pilot goes 

      out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.   

WARNING

: Make sure that while the input gas type is NG, pilot burner NG ignites; while the input type is LP, pilot burner LP 

      ignites. Note: If you find anything abnormal in this step, repeat steps 2 through 8.
9.   Turn control knob counterclockwise to the desired heating level. The main burner should light. Set control knob to any heat 

      level between HI and LO (5 –1).

Содержание FBD2810T

Страница 1: ...his manual with the appliance CONSUMER Retain this manual for future reference WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE...

Страница 2: ...arting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS Model FBD28T VENT FREE GAS FIREPLACE INSERT Input Rating...

Страница 3: ...sory not approved for use with this heater Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable materi...

Страница 4: ...d items can cause sooting Do not add lava rock around base Rock and debris could fall into the control area of heater After servicing always replace screen before operating heater 16 This heater is de...

Страница 5: ...sed plumber or gas fitter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale...

Страница 6: ...of water for every 1 000 BTUs 3 kw of gas input per hour An unvented room heater is recommended as a supplemental heater a room rather than a primary heat source an entire house In most supplemental...

Страница 7: ...art of the unconfined space This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air Adjoining...

Страница 8: ...ter logs ________ BTU hr Gas water heater 30 000 BTU hr Other gas appliances ___BTU hr Vent free heater 26 000 BTU hr Total ________________ BTU hr Total 56 000 BTU hr Do not include direct vent gas a...

Страница 9: ...ing to an adjoining unconfined space you must provide two permanent openings one within 12 inches of the wall connecting the two spaces see options 1 and 2 Fig 2 You can also remove door into adjoinin...

Страница 10: ...tc in the air exist may cause walls to discolor WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and back walls IMPORTANT Vent free h...

Страница 11: ...ons shown in Fig 8 for the rough opening The height is 26 1 2 in which is the same as the wall opening above 2 Carefully set fireplace in front of rough opening with back of fireplace inside wall open...

Страница 12: ...ombustible materials to cover any necessary openings like louvered slots WARNING Never modify or cover the louvered slots on the front of the firebox Step 1 Step 3 Step 2 Fig 9 Remove two screws on to...

Страница 13: ...cceptable alternative to test gauge connection Purchase the optional CSA design certified equipment shutoff valve from your dealer WARNING Never connect heater to private non utility gas wells This ga...

Страница 14: ...end that you install a sediment trap in a supply line as shown in Fig 12 Locate sediment trap where it is within reach for cleaning and not likely to freeze Install in the piping system between fuel s...

Страница 15: ...rter and turn knob clockwise until the knob locks into the NG position see Fig 14 3 Rotate and close cover over fuel selection device and reinstall screw 4 Remove steel or metal hex plug with wrench p...

Страница 16: ...eater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig 16 2 Pressure supply...

Страница 17: ...ns in this manual Flames contacting logs will create soot Fig 18 Installing Log Set IMPORTANT Make sure log does not cover any burner ports see Fig 18 It is very important to install the logs exactly...

Страница 18: ...ap and install a AAA battery with the pointing out Replace cap 1 STOP Read the safety information on page 18 2 Warning You must operate this heater with the screen in place Make sure screen is install...

Страница 19: ...ote The thermostat sensing bulb measures the temperature depending on housing construction TO TURN OFF GAS TO APPLIANCE Shut off heater Turn Control Knob clockwise to the OFF position Do not force MAN...

Страница 20: ...ame Pattern Fig 22 Correct Pilot Flame Pattern with Control Knob Set to High Flame 5 Fig 23 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 Fig 21 Incorrect Pilot Flame Pattern BUR...

Страница 21: ...pet hair etc The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust dirt and lint Clean these air inlet hole...

Страница 22: ...Depleted gas supply 1 Turn on gas supply or open equipment shutoff valve 2 Fully press in control knob while pressing ignitor button 3 Continue holding down control knob for 30 seconds to remove air R...

Страница 23: ...ct qualified service technician White powder residue forming within burner box or on adjacent walls or furniture 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white...

Страница 24: ...ZY WORLD PHONE NUMBER 800 776 9425 When contacting your dealer have ready Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used natural or propa...

Страница 25: ...B 10 Fuel Selection Device Assembly YDF06 FBD28T 11 Hood FB28D04 B 12 Logs Set FB28D500 C 13 Log 1 FB28D501 C 14 Log 2 BL037 02 B 15 Log 3 BL038 02 B 16 Log 4 BL041 02 17 Log 5 FB28D505 C 18 Screen F...