  OPERATING INSTRUCTIONS

WARNING

Do not operate appliance with the glass front removed, cracked, 

or broken. Replacement of the glass should be done by a licensed 

or qualified service person.
Under no circumstances should any solid fuel (wood, coal, paper, 

cardboard, etc.) be used in this appliance.
Children and adults should be alerted to the hazards of high 

surface temperature and should stay away to avoid burns or 

clothing ignition.

CAUTION

Clothing or other flammable material should not be placed on or 

near the appliance.
Young children should be carefully supervised when they are in the 

same room as the appliance. Toddlers, young children and others 

may be susceptible to accidental contact burns. A physical barrier 

is recommended if there are at risk individuals in the house. To 

restrict access to a fireplace or stove, install an adjustable safety 

gate to keep toddler, young children and other at risk individuals 

out of the room and away from hot surfaces.

WARNING: 

If you do not follow these instructions exactly, a fire or explosion may result causing property damage, 

personal injury, or loss of life.

STOP! Read all the safety information above on this page. 
Press the wireless remote OFF button. 
Turn off all electric power to the appliance. 
This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot 
by hand.

Locate the manual valve installed by your qualified service 

technician.

Turn the manual valve clockwise to 

the OFF position. 

Wait five (5) minutes to clear out 

any gas. Then, 

smell for gas, including near the floor. If you smell gas, 
STOP! 
Follow ‘B’ in the safety information above. If you do not 
smell gas, go to the next step. 

Turn the manual valve counterclockwise  

to the ON 

position. 

Turn on all electric power to the appliance. 
Press the wireless remote ON button. 
If the appliance will not operate, follow the instructions, 

“To Turn Off Gas To Appliance” and call your service 
technician or gas supplier. 

OPERATING INSTRUCTIONS

NOTE

When this fireplace is initially lit, condensation will appear on the glass. This is normal in all gas fireplaces and will disappear after 
several minutes. A paint smell will occur during the first few hours of burning. It is recommended to leave the fan off during this period to 
help speed the paint curing process. This fireplace may produce noises of varying degree as it heats and cools due to metal expansion 
and contraction. This is normal, and does not affect the performance or longevity of the fireplace.

A. 

This appliance is equipped with an ignition device which 

automatically lights the pilot. Do not try to light the pilot by 

hand. 

B. 

BEFORE OPERATING

 smell around the appliance area for 

gas. Be sure to smell next to the floor because some gas is 

heavier than air and will settle on the floor. 
WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electric switch; do not use any phone 

in your building.

•  Immediately call your gas supplier from a neighbor’s 

phone. Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire 

department. 

C. 

Use only your hand to turn the gas control manual valve. 

Never use tools. If the valve will not turn by hand, do not 

try to repair it; call a qualified service technician. Force or 

attempted repair may result in a fire or explosion. 

D. 

Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control that has been under water. 

ON/OFF 

ON

OFF

1. 

Press the wireless remote OFF button.

2. 

Turn off all electric power to the appliance if service is to 
be performed. 

3. 

Locate the manual valve installed by your qualified service 
technician.

4. 

Turn the manual valve clockwise 

to OFF position. 

FOR YOUR SAFETY READ BEFORE OPERATING

TO TURN OFF GAS TO APPLIANCE

10.0  OPERATING INSTRUCTIONS

Содержание TRF-41 LOG

Страница 1: ...FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage This appliance may be installed in an aftermarket permanently located manufa...

Страница 2: ......

Страница 3: ...r safety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeown...

Страница 4: ......

Страница 5: ...pproved 4 x 65 8 Vent Systems 22 7 2 Venting Requirements 22 7 3 Use of Elbows 22 7 4 Restrictor Assembly and Installation 22 7 5 Vertical Terminations 23 7 6 Combination Venting 23 7 7 700 1 Series D...

Страница 6: ......

Страница 7: ...tor as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 1 2 3 Signage A metal or plastic identification plate shall be permanent...

Страница 8: ...3 8 WC 0 95 kPa 11 WC 2 74 kPa Manifold Pressure Low 1 1 WC 0 27 kPa 2 9 WC 72 kPa Orifice Size DMS 40 0625 2 2 1 Altitude Adjustment This appliance may be installed at higher altitudes Please refer t...

Страница 9: ...g Height Stand off Height Back to Vent Center Inches 34 1 2 40 3 4 22 1 2 15 3 4 36 26 3 1 2 6 3 4 Millimeters 876 1035 572 400 914 660 89 171 15 401mm 22 572mm 6 171mm 23 16 56mm 53 8 137mm 39 16 91m...

Страница 10: ...r shall be replaced with Hussong Mfg s barriers for this appliance Only doors certified with the appliance shall be used For installation and mounting options please refer to Section 4 3 Safety Barrie...

Страница 11: ...any additional framing This fireplace may be installed in a bedroom Please be aware of the large amount of heat this fireplace will produce when determining a location 3 2 Top Stand off Adjustment WA...

Страница 12: ...4 in 6 mm To flooring 0 in 0 mm Unit top to ceiling 31 in 787 mm Unit side to adjacent sidewall 1 1 2 in 38 mm Unit front to side trim 1 in 25 mm Mantel 9 in 229 mm deep from fireplace enclosure floo...

Страница 13: ...dimensions should allow for wall covering thickness and fireplace facing materials If using a hearth adjust the rough opening size as necessary to maintain minimum clearance requirements If masonry is...

Страница 14: ...ight If a hearth extension is desired combustible material may be used 3 6 Recess Construction WARNING All clearances to venting must be maintained Mounting a television above a fireplace has become a...

Страница 15: ...TE Elbows listed with approved vent systems for this appliance vary in vertical length Please consult the vent manufacturer s instructions to determine the elbow dimension used for installation Adjust...

Страница 16: ...cing away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flange until parallel with fireplace...

Страница 17: ...FACING AND FINISHING 17 4 2 Mantel Requirements NONCOMBUSTIBLE ZONE 9 229mm 42 1067mm FIREPLACE ENCLOSURE FLOOR COMBUSTIBLE MANTEL...

Страница 18: ...tabs are firmly in position To remove safety screen lift the screen up and out of slots 4 3 2 Overlap Fit Hanging Installation Models TRF PSF TRF FRSF TRFR MSF and TRFA MSF 1 Center the screen front o...

Страница 19: ...ssures in excess of psi 3 5 kPa For test pressures equal to or less than psi 3 5 kPa the appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve A...

Страница 20: ...r 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1 22 Over 12 12 to 14 12 5 0 1 52 Over 14 12 to 16 12 6 0 1 83 Over 16 12 to 18 12 7 0 2 13 Over 18 12 to 20 12 7 5 2 27...

Страница 21: ...combustion air inlet to any other appliance 12 in 30 cm 9 in 23 cm K Clearance to mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if within 10 ft 3 m horizontally Massachusetts 10 ft 3 m L Cl...

Страница 22: ...pliance after the fireplace is installed 7 2 1 Vent Section Clearances Table 7 1 Vertical Pipe Section Clearances Surface Sides All Approved Venting 1 in 25 mm Table 7 2 Horizontal Pipe Section Cleara...

Страница 23: ...nimum horizontal venting Refer to Section 7 8 on page 25 IMPORTANT Horizontal vent sections require in 6 mm rise for every 12 in 305 mm of travel Table 7 4 NG LPG Minimum Horizontal Vent Terminations...

Страница 24: ...ermination box A placing assembly through the wall pass through in exterior wall Place screws through the four holes B securing it in place 3 Form the 4 7 flexible aluminum pipes on termination kit 74...

Страница 25: ...ges with corresponding screw holes located in front of the flue outlet on the top of the fireplace 3 Secure the vertical vent heat shield to the fireplace with 2 attachment screws provided in the comp...

Страница 26: ...oaded latches out and up to secure the bottom of glass to the bottom of the fireplace 8 2 TRF 500B Log Set Installation CAUTION Do not place logs directly over burner port holes Improper log placement...

Страница 27: ...alignment hole over the pin on the front of the log brackets Push to seat 3 Position 3 log cutouts over log grate Align the log s right side alignment hole over the pin on the front of the log bracket...

Страница 28: ...screws 10 Remove log grate burner heat shield 11 Remove and save 6 screws securing control board Lift the control board out of the firebox being careful not to damage the sealing gasket underneath 8 3...

Страница 29: ...t or remove the grounding prong from this plug 9 1 Electrical Specifications This appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes...

Страница 30: ...ill not operate follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier OPERATING INSTRUCTIONS NOTE When this fireplace is initially lit condensation will...

Страница 31: ...osition for remote control operation of the main burner and fireplace features 10 3 Reset the System for Manual Operation 1 Set the ON OFF rocker switch to OFF position 2 Press the red SWI button on t...

Страница 32: ...imately 2 seconds move the switch to the ON position The ignition sequence will start again 10 6 1 2 Remote Control ON OFF Key 1 Press the remote control ON OFF key to turn the system OFF 2 After appr...

Страница 33: ...lot option The standing pilot will keep the firebox warm and establish a draft in the vent which allows the main burner to ignite with less air flow disruption When the system is OFF the LCD screen wi...

Страница 34: ...be set to a desired temperature to control a room s comfort level To activate this function 1 Press the thermostat key The LCD screen will display a temperature bulb graphic the room temperature and s...

Страница 35: ...s will operate at previous setting There is no delay in start up or stop time 10 8 9 Accent Light Kit if applicable The light intensity can be adjusted through 6 levels 1 Press the mode key to index...

Страница 36: ...ximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not over tighten 6 Relight pi...

Страница 37: ...y lift off the burner Table 11 3 Factory Set Venturi Openings Fuel Air Shutter Opening Natural Gas 1 8 3 mm OPEN LP Gas 5 8 15 mm OPEN 11 2 1 1 Venturi Adjustment NOTE If soot is present on the glass...

Страница 38: ...ve 2 screws securing baffle Remove baffle to expose venting 4 Bend the tabs on the restrictor included in fireplace components packet to approximately 80 angles This will create tension when the restr...

Страница 39: ...t No LP propane gas in tank Check LP propane tank Refill if necessary Low gas pressure Consult a plumber or a gas supplier Can be caused by situations such as a bent line too narrow diameter or pipe o...

Страница 40: ...6 Improper venturi setting Venturi air shutter may need to be opened slightly to allow more air into the gas mix Refer to Section 11 2 1 Burner Venturi on page 37 Incorrect vent cap installation Adjus...

Страница 41: ...electrical current and vacuum The bearings are sealed and require no oiling 13 3 Vent System NOTE If the vent air intake system is disassembled for any reason reinstall per instructions provided with...

Страница 42: ...51 Conversion Kit NG NCK TRF S Pilot Assembly LPG 700 551 1 Conversion Kit LPG LCK TRF S Transmitter Remote Control 700 408 Burner Tube TRF 035 Pilot Orifice NG 700 094 Burner Plate TRF 35 Pilot Orifi...

Страница 43: ...ng Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit It is expressly agreed and understood that this warranty is Hussong Manufacturing Co Inc s sole obligati...

Страница 44: ......

Страница 45: ...efective component s It is expressly agreed and understood that this Lifetime Warranty is Hussong Manufacturing Co Inc s sole obligation and original purchaser s exclusive remedy for defective firepla...

Отзывы: