26
FIREPLACE SETUP
8.0 FIREPLACE SETUP
8.1 Glass Frame Assembly
WARNING: Do not operate this fireplace with the glass removed,
cracked, or broken. Replacement of the glass assembly, should
be done by a licensed or qualified service person.
8.1.1 Remove Glass Frame Assembly
WARNING: Do not remove the glass assembly when hot.
1. Locate (2) spring-loaded latches securing the glass assembly
at the bottom of the firebox.
2. Pull the spring-loaded latches out and down to release the
bottom of the glass assembly.
3. Life glass assembly up and off of the (2) tabs located at the
top of the firebox.
8.1.2 Install Glass Frame Assembly
1. Align the slots on top of the glass assembly over the tabs at
the top of the firebox while lowering the bottom of the glass
assembly into position.
2. Pull the spring-loaded latches out and up to secure the
bottom of glass to the bottom of the fireplace.
8.2 #TRF-500B Log Set Installation
CAUTION: Do not place logs directly over burner port holes.
Improper log placement may affect flame appearance and
cause excessive soot to build upon the logs and glass.
• If converting to LP (propane) gas, complete the conversion
before installing the log set. Follow the conversion
instructions included with the kit.
• Log numbers are located on the bottom of each log. Refer
to the following instructions and illustrations for proper log
placement.
8.2.1 LP Log Plate
If an optional firebrick refractory set is to be installed for LP gas
models,
1. Remove the break away tab at the front of the LP log plate.
2. Position LP Log plate onto the back log bracket.
3. When the plate is properly seated, the sides will sit between
the back log brackets and the sides of the burner heat shield.
See Figure 8.1.
Log placement instructions are on the following page.
Figure 8.1, LP Log Plate