9
EXISTING FIREPLACE SPECIFICATIONS
THIS INSERT IS APPROVED FOR INSTALLATION IN MASONRY AND FACTORY-BUILT SOLID FUEL BURNING FIREPLACES
EXISTING FIREPLACE REQUIREMENTS
The existing fireplace & chimney must be clean and in good working order and constructed
of non-combustible materials.
A gas line must be able to be installed to the insert.
Provisions made to provide electrical power for operation.
Any chimney clean-outs must fit properly.
Existing Chimney must be comprised of one of the following:
Factory built solid fuel chimney: 7” minimum inside diameter.
Masonry chimney: 6" x 8" minimum inside diameter.
Existing Chimney Height: Minimum: 10ft. (3.05m)
Maximum: 35ft. (10.67m)
1. Remove and discard existing chimney cap.
2. Position one person at fireplace and another person at top of chimney.
Measure from fireplace base to top of chimney.
Subtract 19-3/4” (501mm) (height of insert).
This is the total length of co-linear flexible aluminum you will require.
MEASUREMENT FROM FIREPLACE BASE TO TOP OF CHIMNEY:_________________
LESS 19-3/4" (501mm) (HEIGHT OF INSERT): -19-3/4" (501mm)
TOTAL CHIMNEY LENGTH REQUIRED:
_________________
DETERMINE LENGTH OF EXISTING CHIMNEY
MIN. 10ft. (3.05m)
MAX. 35ft. (10.67m)
Figure 9a
CAUTION
This appliance must not be connected to or joined with any other chimney flue serving another appliance.
NOTE
It is helpful to have two people complete next step to determine chimney height.
EXISTING FIREPLACE MINIMUM OPENING REQUIREMENTS
Figure 9b
A
Height
20-5/8” (524mm)
B
Front Width
30-5/16” (770mm)
C
Depth
16” (406mm)
D
Back Width
24-5/16” (618mm)
Содержание JOR-30