26
FLAME MODE:
This remote will operate the flame, allowing for (6) different flame height
levels. When
MAIN FLAME
button is pressed, FLAME level setting will
flash on the LCD screen. Press
UP
or
DOWN
buttons to select desired flame
level. If no adjustment is made within 7 seconds, the control will exit function
setting mode and LCD display will return to normal view.
REMOTE CONTROL INFORMATION cont.
Figure 26a
NOTE
The fireplace will initially light at the highest level.
After 5 seconds the flame will adjust to last chosen
level before fireplace was turned OFF.
This applies to MANUAL and THERMO modes.
THERMO (THERMOSTAT) MODE:
This remote feature allows you to thermostatically control the fireplace when hand held remote is set to
THERMO
mode.
Set Temperature Range: 45
˚
F (7
˚
C) to 90
˚
F (32
˚
C).
Set remote to
THERMO
mode by pressing
MODE
button. The smaller
SET
window
of numbers appears
on the LCD screen. The first SET number will read 45
˚
F. Press
UP
button to desired set room temperature.
Within 5 seconds fireplace will operate to that Set Temperature. The
FLAME, ON
and
THERMO
icons
will appear on the LCD screen. By pressing
UP
or
DOWN
buttons a new set temperature may be attained.
SET Temperature will only appear when THERMOSTAT MODE is activated,
but is implemented in all MODES with the exception of MANUAL MODE.
To exit
THERMO
mode press the
MODE
button. This also shuts fireplace OFF.
SYSTEM OPERATION WITHOUT HAND HELD REMOTE:
This system is designed to operate with the hand held remote or a thermostat, but in the unlikely event that it is required to be operated
without the hand held remote or a thermostat, follow this simple procedure.
Slide
REMOTE/OFF
switch on main control module to
OFF
. The fireplace can now be lit and shut off by use of the ON/OFF rocker switch.
REMOTE / OFF
Figure 26c
Figure 26b
NOTE
The flame height can adjust up to (6) different height levels according to amount of heat
required. This range however is dictated by the Flame Level setting (see previous page).
When desired temperature is met, the fireplace will shut off until more heat is required.
IMPORTANT
When in THERMO mode the fireplace will not turn on until room temperature falls below
SET TEMPERATURE.
NOTE
When operating fireplace in this capacity, the only function available is burner operation on HI.