Any removed parts must be capable of reinstallation if this insert is ever removed (removal of rivets or screws is acceptable).
The refractory, glass doors, screen rails, screen mesh and log grates may be removed from existing fireplace before installing this gas
fireplace insert. Any smoke shelves, shields and baffles may be removed if attached by mechanical fasteners. If necessary, remove firebrick
to obtain at least minimum opening requirements.
The fireplace flue damper can be fully blocked open or removed for installation of this gas fireplace insert. Remove existing chimney cap.
Clean chimney and inside of fireplace to prevent creosote smell from entering the home.
Cutting of any sheet metal parts is prohibited, except the metal floor. If metal floor is removed, the insert must be placed directly on metal
base of metal fireplace. If using this method,
Kozy Heat Floor Protector Kit (#JOR-FLP)
, must be used.
Place ‘THIS UNIT HAS BEEN MODIFIED’ label at bottom of existing firebox so it will be visible if this gas fireplace insert is removed.
Run any necessary electrical wiring to insert.
PREPARE EXISTING FIREPLACE
ELECTRICAL WIRING
This fireplace insert comes complete with a fan kit already installed. A double receptacle and power cord have been installed, wired and
mounted in a removable electrical box panel on right side of fireplace
WIRING SCHEMATIC
Figure 10a
NOTE
If wiring to pre-installed electrical box is desired, wiring should be run prior to permanently positioning insert and connecting
vent system.
If this fireplace insert is being installed in minimum opening dimensions, wiring may need to be completed after fireplace insert
is set in place.
NOTE
DIRECT WIRE INSTALLATION: Remove existing cord and insert 110V-120V wiring (with ground) through romex connector,
wiring to box cover assembly, matching black (hot), white (neutral), and green (ground) wires to corresponding wires on box
cover assembly using (3) wire nuts obtained when removing existing cord.
ATTENTION
Any removed parts must be capable of reinstallation if this insert is ever removed (removal of rivets or screws is acceptable).
NOTE
The appliance, when installed, must be electrically grounded and connected in accordance with local codes, or in the absence of local codes, with
the
National Electrical Code, ANSI/NFPA 70
, or the
Canadian Electrical Code CSA C22.1.
WARNING
MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND
SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE
GROUNDING PRONG FROM THIS PLUG.
EXISTING FIREPLACE SPECIFICATIONS
Содержание JOR-30
Страница 2: ......
Страница 4: ......
Страница 10: ...7 SPECIFICATIONS MINIMUM CLEARANCES TO COMBUSTIBLES Figure 7a 3 76mm Combustible Material ...
Страница 40: ......
Страница 42: ......
Страница 44: ......
Страница 50: ...6 CONTROL SYSTEM COMPONENTS FAN CONTROL MODULE Figure 6a RECEIVER DFC CONTROL BOARD Figure 6c Figure 6b ...
Страница 65: ......