Roof Pitch 

H (Min.) Ft.  H (Min.) m 

Flat to 6/12 

1.0 

0.30 

Over 6/12 to 7/12 

1.25 

0.38 

Over 7/12 to 8/12 

1.5 

0.46 

Over 8/12 to 9/12 

2.0 

0.61 

Over 9/12 to 10/12 

2.5 

0.76 

Over 10/12 to 11/12 

3.25 

0.99 

Over  11/12 to 12/12 

4.0 

1.22 

Over 12/12 to 14/12 

5.0 

1.52 

Over 14/12 to 16/12 

6.0 

1.83 

Over 16/12 to 18/12 

7.0 

2.13 

Over 18/12 to 20/12 

7.5 

2.27 

Over 20/12 to 21/12 

8.0 

2.44 

H

12

X

ROOF PITCH = X/12

H (minimum)

 - MINIMUM HEIGHT FROM ROOF 

TO LOWEST DISCHARGE OPENING

APPROVED CAP

APPROVED VENT PIPE

DISCHARGE OPENING

*8' MIN

*

 - IF VENT IS CLOSER THAN 8', IT MUST 

TERMINATE AT LEAST 2' HIGHER THAN ANY 

PORTION OF A BUILDING WITHIN 10' OF THE VENT

VENT TERMINATION CLEARANCES 

CAUTION: This appliance must 
not be connected to or joined 
with any chimney flue serving 
any other appliance. 

                                        VENTING   

(Vertical Cap Requirements)

                             

*(2.44 m) 

IF VENT IS CLOSER THAN 8’ (2.44 m), IT MUST TERMINATE AT 

LEAST 2’ (0.61 m) HIGHER THAN ANY PORTION OF A BUILDING 
WITHIN 10’ (3.05 m) OF THE VENT. 

PAGE 36 

Содержание Dassel DSL-36-RF

Страница 1: ...you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these i...

Страница 2: ...ourselves in being dedicated to not only function and reliability but customer safety as well We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from you...

Страница 3: ...zontal Terminations 14 Vertical Terminations 14 TYPICAL INSTALLATION OPTIONS Typical Installation Options 15 MANTEL REQUIREMENTS Mantel Requirements 16 GLASS FRAME ASSEMBLY Glass Frame Assembly Remova...

Страница 4: ...ion 37 40 MILLIVOLT BOARD Millivolt Board Removal 41 Millivolt Board Installation 42 GRILL SET Grill Set Installation 43 Grill Set Removal 43 DSL 36 OPERATION PROCEDURES DSL 36 Valve and Pilot Assembl...

Страница 5: ...appliance should be located out of traffic and away from furniture and draperies The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance Work...

Страница 6: ...te control Wall mount thermostat wireless wall mount thermostat Decorative full door faces in various styles and finishes Renaissance pattern front Mission design doors in various finishes Various cab...

Страница 7: ...and battery back up may be installed on the next adjacent floor level In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall ha...

Страница 8: ...anufacturer of Product Approved side wall horizontally vented gas equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shal...

Страница 9: ...15 1 4 387 mm C 27 7 8 708 mm G 10 254 mm A 32 813 mm F 24 3 8 619 mm WARNING NON COMBUSTIBLE ZONE STAND OFFS PROVIDE THE 10 254 mm MINIMUM CLEARANCE TO HEADER USE ONLY NON COMBUSTIBLE MATERIAL IN TH...

Страница 10: ...e configurations on page 16of this installation manual SPECIFICATIONS RIGHT SIDE LEFT SIDE GAS LINE HOLE ELECTRICAL ACCESS PAGE 9 8 3 8 213 mm 5 1 2 140 mm 9 1 2 241 mm CLEARANCES 2 3 4 70 mm STAND OF...

Страница 11: ...earances at this point 10 Install facing material mantel or cabinetry allowing room for optional full face doors if applicable 11 Install logs 12 Install grills and optional decorative doors faces 13...

Страница 12: ...FINISH MATERIAL USED STAND OFF ASSEMBLY INSTALLATION IMPORTANT THE TOP STAND OFF BRACKETS MUST BE FORMED AND ATTACHED PRIOR TO POSITIONING THE FIREPLACE INTO FRAMED OPENING PAGE 11 WARNING NON COMBUST...

Страница 13: ...d perforation on nailing flange until parallel with fireplace face Do not bend toward fireplace face 4 Position framing stud against the 1 4 6 mm stand off located on the backside of the nailing flang...

Страница 14: ...lower grill open and close optional decorative doors full door faces access the control valve installation of gas line fan etc PAGE 13 IMPORTANT NON COMBUSTIBLE FACING MATERIAL MAY BE APPLIED OVER THE...

Страница 15: ...n all sides of vertical vent pipe must be maintained VERTICAL TERMINATIONS MINIMUM HORIZONTAL FRAMING DIMENSIONS VENT PIPE TOP A FRAMED OPENING TOP B RIGID PIPE 42 1 8 1070 mm 45 1 8 1146 mm FLEX PIPE...

Страница 16: ...D WHEN USING A 90 DEGREE ELBOW DIRECTLY OFF THE TOP OF UNIT TO HORIZON TALLY POSITION THE VENT SYSTEM THIS INCLUDES ANY CORNER INSTALLATION 1 4 6 mm clearance IMPORTANT The illustration below shows th...

Страница 17: ...DO NOT USE WOOD SHEET ROCK ETC IN THIS ZONE NOTE OTHER CLEARANCES APPLY THESE CLEARANCES MUST BE MAINTAINED NON COMBUSTIBLE ZONE NO COMBUSTIBLE MATERIALS ALLOWED ON TOP OF FIREPLACE WITHIN THE SHADED...

Страница 18: ...ront B Pull top handles out and down to secure glass frame assembly top C Pull bottom handles out and up to secure glass frame assembly bottom CAUTION TO PREVENT GLASS FRAME ASSEMBLY FROM FALLING OFF...

Страница 19: ...his assembly Refer local electrical codes for specific requirements WARNING THIS APPLIANCE IS EQUIPPED WITH A THREE PRONG GROUNDING PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIREC...

Страница 20: ...if necessary Before adjusting the temperature control switch unplug the 3 prong plug on the fan cord from the receptacle Adjust position of the temperature control switch to a warmer location under t...

Страница 21: ...inches W C MANIFOLD PRESSURE LO 1 1 inches W C 6 3 inches W C 1 7 inches W C 6 3 inches W C ORIFICE SIZE 42 53 3 32 093 53 INPUT BTU hr 26 000 24 000 26 000 24 000 MINIMUM INPUT BTU hr 13 000 12 000...

Страница 22: ...placed over the remote receiver to prevent overheating IMPORTANT If ON OFF rocker switch wires are not disconnected the ON OFF rocker switch on the millivolt board must be in the OFF position for pro...

Страница 23: ...ocal and national installation codes to assure adequate combustion and ventilation air is avail able HORIZONTAL VENT SYSTEM CLEARANCES TOP BOTTOM SIDES DURA VENT 3 inches 76 mm 1 inch 25 mm 1 inch 25...

Страница 24: ...thickness cut insulation panel included this length B Install wall pass thru section marked 1 with 3 8 10 mm flange into framed opening Secure to interior wall with screws not provided C From the exte...

Страница 25: ...AL TERMINATIONS MINIMUM HORIZONTAL VENTING MAXIMUM HORIZONTAL VENTING 5 X 8 CAUTION This gas appliance must not be connected to or joined with any other chimney flue serving another appliance PAGE 24...

Страница 26: ...eld for clarity purposes only 90 elbow horizontal pipe termination cap Horizontal Vent Heat Shield required IMPORTANT THE HORIZONTAL HEAT SHIELD INCLUDED WITH THIS FIREPLACE MUST BE INSTALLED WHEN USI...

Страница 27: ...INCLUDES ANY CORNER INSTALLATION HORIZONTAL VENT HEAT SHIELD VENTING 1 Loosen but do not remove center three screws on top of fireplace 2 Bend horizontal heat shield at perforation to a 90 angle Slide...

Страница 28: ...e IMPORTANT Depending on your particular venting needs a Decreaser may be necessary to terminate the venting system PAGE 27 6 152 mm 2 FT 610 mm MAXIMUM HORIZONTAL VENTING 25 ft 7 62 m maximum or 30 f...

Страница 29: ...sed on vertical venting configurations A restrictor included in fireplace components packet is recommended on all vertical terminations over 6 1 82 m in length Each installation is unique and affected...

Страница 30: ...ed on vertical venting configurations 4 FT 1 22 m 40 FT 12 19 m TERMINATION CAP RESTRICTOR INSTALLATION LARGE RESTRICTOR REMOVE TAB TO CREATE SMALL RESTRICTOR SLIDE RESTRICTOR INTO EXHAUST PIPE ON TOP...

Страница 31: ...particular venting needs a Decreaser may be necessary to terminate the venting system NOTE Horizontal Vent Heat Shield is not used on vertical venting configurations 4 FT 1 22 m 40 FT 12 19 m 8 x 6 5...

Страница 32: ...ON VENTING 5 x 8 NOTE Horizontal sections require 1 4 6 mm rise for every 12 305 mm of travel PAGE 31 Depending on your particular venting needs a Decreaser may be necessary to terminate the venting s...

Страница 33: ...TRUCTIONS FOR THEIR WALL THIMBLE For each additional 90 elbow used after the first elbow 3 ft 914 mm must be subtracted from the maximum venting allowed For each 45 elbow used 1 1 2 ft 457 mm must be...

Страница 34: ...h either interior or exterior walls Use a tin snips to remove inner ring on each thimble section This will provide adequate room for the flexible vent system to be installed Follow directions on page...

Страница 35: ...C 5 FLEX PIPE COLLAR D 5 PIPE ON FIREPLACE OR EXTENSION KIT E 8 FLEX PIPE COLLAR F 8 PIPE ON FIREPLACE OR EXTENSION KIT G VINYL SIDING PROTECTOR A G Bend tabs up before attaching 8 flex pipe collar Se...

Страница 36: ...ft 914 mm horizontally from the centerline of the regulator I Gas Service regulator vent outlet 3 ft 914 mm J Non mechanical air supply inlet to building or the combustion air inlet to any other appli...

Страница 37: ...ROOF PITCH X 12 H minimum MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING APPROVED CAP APPROVED VENT PIPE DISCHARGE OPENING 8 MIN IF VENT IS CLOSER THAN 8 IT MUST TERMINATE AT LEAST 2 HIGHER THA...

Страница 38: ...nstalled in numerical order Log numbers are located on the bottom of each log Refer to following instructions and illustrations for proper placement CAUTION Do not place logs directly over burner port...

Страница 39: ...LOG SET INSTALLATION STEP 2 D2 D3 Log Placement D2 D3 PAGE 38 PLACE THE FRONT LOGS ON THE BURNER BY ALIGNING HOLES IN THE BOTTOM OF LOGS WITH THE PINS ON THE BURNER...

Страница 40: ...5 STEP 3 D4 D5 D6 Log Placement D6 PAGE 39 PLACE THE TOP LOGS BY ALIGNING WITH NOTCHES IN REAR LOG AS SHOWN PLACE EMBER CHUNK BY ALIGNING GROOVE IN BOTTOM WITH LOG GRATE AS SHOWN ALIGN NOTCHES IN LOGS...

Страница 41: ...4 COMPLETE LOG SET INSTALLATION PAGE 40 RANDOMLY PLACE KLINKERS IN THIS AREA DO NOT PLACE KLINKERS DIRECTLY ON BURNER USE A STEEL OR STIFF BRISTLE NYLON BRUSH TO DISTRIBUTE ROCK WOOL EMBERS ONTO LOGS...

Страница 42: ...y Refer to page 17 if necessary 7 Remove logs and bottom refractory panels 8 Remove pilot shield 9 Remove refractory panel set if in stalled 10 Remove the burner burner heat shield assembly from fireb...

Страница 43: ...erminals on the gas valve Model DSL 36 RF Re connect the 2 wires to fan cord Plug fan cord into receptacle 9 Reinstall glass frame assembly Page 17 10 Reinstall upper louver upper hood and lower grill...

Страница 44: ...ding holes in the inside flange of the lower grill opening The lower grill can now be opened and closed to access the gas valve and controls A Use both hands to pull the hood out of upper air passage...

Страница 45: ...VALVE TERMINALS GAS CONTROL KNOB PIEZO IGNITOR HI LO FLAME ADJUSTMENT KNOB ON OFF ROCKER SWITCH ELECTRODE PILOT HOOD THERMOPILE THERMOCOUPLE PILOT SHIELD DSL 36 VALVE PILOT ASSEMBLY COMPONENTS PAGE 44...

Страница 46: ...LIANCE DUE TO HIGH SURFACE TEMPERATURES KEEP CHILDREN CLOTHING AND FURNITURE AWAY This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustio...

Страница 47: ...ave accumulated inside the firebox to escape If you then smell gas STOP Follow the safety information on the front cover and on page 45 of this installation manual If you don t smell gas go to the nex...

Страница 48: ...p off wall switch or adjust setting on the thermostat or remote control NOTE The pilot will stay lit H Turn the pilot off by pushing in and turning the gas control knob to the OFF position DO NOT FORC...

Страница 49: ...switch to OFF 7 Disconnect manometer hose and tighten screw clockwise Screw should be snug do not over tighten 8 Attach manometer to manifold pressure tap to verify that it is completely sealed Manome...

Страница 50: ...ODE THERMOPILE PILOT PAGE 49 PIEZO MOTOR GAS CONTROL KNOB INLET PRESSURE TAP OUTLET PRESSURE TAP LED FUEL CONVERSION PLUG ANTENNA PILOT ADJUSTMENT SCREW THERMOPILE MOTOR COVER WHITE DOTS FAN TERMINALS...

Страница 51: ...DUE TO HIGH SURFACE TEMPERATURES KEEP CHILDREN CLOTHING AND FURNITURE AWAY This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and...

Страница 52: ...hin two or three pushes on the piezo ignitor Hold the knob for about one 1 minute after the pilot is lit Release knob and it will pop back out Pilot should remain lit If it goes out repeat steps A C D...

Страница 53: ...ceiver valve will be at the highest setting LOCAL SETTING Turn control knob clockwise to the PILOT position REMOTE SETTING The TR8220A transmitter can shut off the main burner and fan However the cont...

Страница 54: ...essure tap using a 1 4 I D hose 4 Turn gas control knob to ON Note manometer reading 5 Disconnect manometer hose and tighten screw clockwise Screw should be snug do not over tighten 8 Attach manometer...

Страница 55: ...not receive a signal within 6 hours from the transmitter The negative leads white must be connected to the terminals with the white dots marked on them LED TROUBLESHOOTING In normal operation LED blin...

Страница 56: ...transmitter in a heated living space to make sure the main burner is not on continuously ON Mode With the control in the ON mode the flame and fan levels and the delay timer are changed with the UP a...

Страница 57: ...TION FLAME COLOR VENTURI ADJUSTMENT Closed too far Dark orange flame with black tips Open venturi setting slightly Open too far Blue flames Close venturi setting slightly NOTE IF SOOT IS PRESENT CHECK...

Страница 58: ...restrictor into 5 exhaust pipe with tabs pointing towards you 4 If modification is necessary remove restrictor by pulling it down and out of 5 exhaust pipe 5 Reinstall baffle securing with the 4 screw...

Страница 59: ...LD BE DONE ONLY BY QUALIFIED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CA...

Страница 60: ...LIGHTING INSTRUCTIONS A Check that pilot flame impinges on thermocouple Clean and or adjust pilot for maximum flame impingement B Ensure the thermocouple connection at gas valve is fully inserted and...

Страница 61: ...d TROUBLESHOOTING DSL 36 only BURNER WILL NOT LIGHT FREQUENT PILOT OUTAGES A Pilot shield not installed B Pilot flame too high or too low causing pilot safety to drop out Clean and adjust flame for ma...

Страница 62: ...horizontal vent 1 4 6 mm rise per foot is required on horizontal venting E Inner vent pipe leaking exhaust gases back into firebox Check for leaks Repair if necessary F Improper vent cap installation...

Страница 63: ...trol the main burner and fan Does transmitter change levels of flame height fan speed and set temperature Set levels of flame height and fan to 0 to shut off main burner and fan If the manual switch i...

Страница 64: ...n tank Check LP propane tank Refill if necessary PILOT WILL NOT STAY LIT AFTER CAREFULLY FOLLOWING LIGHTING INSTRUCTIONS A Check that pilot flame impinges on thermopiles Clean and or adjust pilot for...

Страница 65: ...ns PILOT AND BURNER EXTINGUISH WHILE IN OPERATION C Improper pitch on horizontal vent 1 4 6 mm rise per foot is required on horizontal venting D Inner vent pipe leaking exhaust gases back into firebox...

Страница 66: ...H Cap Sconce 58DVAHSC 5x8 H Cap Sconce 46DVASNK36 4x6 Snorkel 48 5x8 High Wind H Cap Squared Sconce 46DVASNK36 4x6 H Cap ICC 5x8 V Cap 5x8 H Cap 5x8 Snorkel 26 5 5x8 Snorkel 28 5x8 Snorkel 50 5x8 Sno...

Страница 67: ...esota 56150 507 662 6641 www kozyheat com REPLACEMENT PARTS LIST PAGE 66 GRILL REPLACEMENT PRC 200 Upper Hood PRC 201 Lower Grill PRC 200L Upper Hood Louver REFRACTORY PANELS Sandstone DSL G900 5 pc R...

Страница 68: ...PAGE 67...

Страница 69: ...PAGE 68...

Отзывы: