6” (152 mm) VENT
PIPE SECTION
VENTING
NOTE: Horizontal sections require 1/4” (6 mm)
rise for every 12” (305 mm) of travel.
IMPORTANT:
THE HORIZONTAL
HEAT SHIELD INCLUDED WITH THIS
FIREPLACE MUST BE INSTALLED
WHEN USING A 90-DEGREE ELBOW
DIRECTLY OFF THE TOP OF UNIT TO
HORIZONTALLY POSITION THE VENT
SYSTEM. THIS INCLUDES ANY
CORNER INSTALLATION
.
IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU
(#800-WPT) MUST BE USED ON ALL HORIZONTAL VENT
RUNS USING 5” x 8” VENTING. FOLLOW INSTRUCTIONS ON
PAGE 23 OF THIS INSTALLATION MANUAL.
HORIZONTAL TERMINATIONS
MINIMUM HORIZONTAL
VENTING
MAXIMUM HORIZONTAL VENTING
5” X 8”
CAUTION: This gas
appliance must not be
connected to or joined
with any other chimney
flue serving another
appliance.
PAGE 24
30 ft.*
(9.14 m)*
HORIZONTAL VENT
HEAT SHIELD
TERMINATION CAP
90° ELBOW
90° ELBOW
HORIZONTAL VENT
HEAT SHIELD
NOTE: Pages 28-29 have information
on restrictor installation in
conjunction with venting installation.
Page 57 has information on restrictor
recommendations depending on
burner flame appearance and
instructions on installation after
venting is completed.
MAXIMUM HORIZONTAL VENTING
25 ft. (7.62 m) maximum, or 30 ft (9.14 m) maximum when
using stainless steel pipe for the entire length of termination.
TERMINATION CAP