background image

15.0  LIMITED LIFETIME WARRANTY

Warranty Coverage

Hussong Manufacturing Company, Inc. (Hussong Mfg.) warrants this 

Kozy Heat gas appliance from the date of purchase to the original 

purchaser, that it is free of defects in materials and workmanship at 

the time of manufacture. Registering your fireplace warranty does not 

require any documents to be sent in to Hussong Mfg. Please retain 

your proof of purchase reflecting the date of purchase along with the 

serial number and model of your fireplace for any future warranty 

claims.

If a defect is noted within the warranty period, the customer should 

contact their authorized dealer for service within 30 days.

30 Days: Parts & Labor*

• 

Paint

• 

Light bulbs

• 

Gasket material 

• 

Glass media and media dam

Year 1: Parts & Labor*

• 

All parts and material except the items listed in the 30 day 

warranty and any exclusions or limitations that may apply.

*Hussong Mfg. will issue labor reimbursement to an authorized dealer 

only. Hussong Mfg. will not be liable for charges occurred as a result of 

any service performed by a non-authorized service provider, without 

pre-authorization. 

Years 2 through Lifetime: Parts Only

• 

Firebox

• 

Heat Exchanger

• 

Logs

• 

Burner tube or pan

• 

Outer shell

• 

Heat shield(s)

• 

Front Viewing Glass (thermal shock only)

• 

Refractory Firebox liner (excluding enamel and glass panels)

EXCLUSIONS AND LIMITATIONS

1.  This appliance must be installed by a licensed, authorized service technician or contractor. It must be installed, operated and maintained 

at all times in accordance with the instructions in the owner’s manual or the warranty is void.

2.  This warranty is nontransferable and is made to the original purchaser only.
3.  This warranty excludes standard wear and tear of the appliance which is considered normal usage over time.
4.  Discoloration and some minor expansion, contraction or movement of certain parts, resulting in noise, is normal and not a defect.
5.  Warranty is automatically voided if the appliance’s serial number and/or testing label is removed or if the appliance is altered or 

tampered with in any way.

6.  Warranty is void if the appliance is subject to submersion in water or prolonged periods of dampness or condensation. Any damage 

to any part of the appliance due to water or weather damage which is the result of, but not limited to, improper chimney/venting 

installation will also render this warranty void.

7.  This warranty does not cover installation and operational related problems such as environmental conditions, nearby trees, buildings, 

hilltops, mountains, inadequate venting or ventilation, excessive offsets, negative air pressures caused by any mechanical systems.

8.  Chimney components and other Non-Hussong Mfg. accessories used in conjunction with the installation of this appliance are not 

covered under this warranty.

9.  Damage to plated surfaces or accessories, if applicable, caused by scratches, fingerprints, melted items or other external sources left on 

the surfaces from the use of cleaners is not covered under this warranty.

10.  It is expressly agreed and understood that this warranty is Hussong Mfg.’s sole obligation and purchaser’s exclusive remedy for defective 

fireplace equipment. Hussong Mfg. is free of liability for any damages caused by this appliance, as well as inconvenience expenses 

and materials. Incidental or consequential damages are not covered by this warranty. In some states, the exclusion of incidental or 

consequential damage may not apply. Hussong Mfg. shall not be held to implied warranties and this warranty shall replace all previous 

warranties.

11.  This limited lifetime warranty is the only warranty supplied by Hussong Mfg. Any warranties extended to the purchaser by the dealer/

distributor, whether expressed or implied, are hereby disclaimed and the purchaser’s recourse is expressly limited to the warranties set 

forth herein.

12.  Any part repaired or replaced during the limited warranty period will be warranted under the terms of the limited warranty for a period 

not to exceed the remaining term of the original limited warranty.

13.  Any replacement part repaired after the warranty period will include a 90 day parts coverage
14.  Hussong Mfg. may require the defective part to be returned using a pre-authorized RGA number or a photo of the defective component. 

Failure to provide either can result in a denied claim.

15.  This warranty does not cover the appliances ability to heat a desired space, as there are many factors that can impact the heating 

performance in each home. Consideration should be implied to the appliance’s location, room size, home design, environmental 

conditions, insulation, and tightness of the home.

16.  Hussong Mfg. reserves the right to make changes at any time, without notice, in design, material, specifications, and prices. Hussong 

Mfg. reserves the right to discontinue models and products.

July 2018

 

SECTION 15

  LIMITED LIFETIME WARRANTY

#CAR-46

R.12  February 2022

62

HUSSONG MFG. CO., INC.

KOZY HEAT FIREPLACES

Содержание CAR-46

Страница 1: ...et permanently located manufactured home USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is...

Страница 2: ......

Страница 3: ...fety We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your Kozy Heat gas fireplace Jim Hussong President Dudley Hussong Board Chairman Homeowner R...

Страница 4: ......

Страница 5: ...Minimum Natural Draft Vent Termination Clearances 32 7 0 VENTING 33 7 1 Approved Vent Systems 33 7 3 Vent Restriction 34 7 4 Vent Heat Shield Assembly Installation 35 7 5 Vent Installation 36 7 6 800...

Страница 6: ......

Страница 7: ...ring said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 1 3 2 Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accord...

Страница 8: ...4 CSA B149 1 Natural Gas and Propane Installation Code local authorities or codes having jurisdiction in you area regarding derate guidelines 2 1 1 1 US Installations Refer to the American Gas Associa...

Страница 9: ...REPLACES 2 3 Appliance Dimensions 7 184mm 223 8 568mm 21 546mm 10 254mm 3015 16 786mm 42 1085mm 45 1162mm 33 16 82mm 133 8 340mm 2 51mm 89 16 217mm 25 16 58mm 36 914mm FRONT VIEW RIGHT SIDE LEFT SIDE...

Страница 10: ...2 2 below for overlap dimensions to ensure the barrier can fit with finishing materials For installation instructions refer to section 4 3 SAFETY BARRIER INSTALLATION on page 28 C46 PSF C46 FRSF C46R...

Страница 11: ...EXTERIOR AND INTERIOR HEAT TRANSFER KIT COVER PLATE S on page 21 If planning to convert to propane it is easier to complete the gas conversion before framing in the fireplace See the LCK C46 D manual...

Страница 12: ...lation piece are adjustable to accommodate the installation of non combustible material If you install the stand off assembly in a forward position the non combustible material will overlap the face o...

Страница 13: ...nstallation Attach the stand off assembly to the fireplace using 4 screws as shown 3 Place the insulation piece in between the two stand off assemblies as shown The insulation piece must be pushed tig...

Страница 14: ...facing away from the fireplace 3 Secure the nailing flanges to the fireplace with screws provided through the slots in nailing flanges 4 Bend perforation on nailing flange until parallel with fireplac...

Страница 15: ...ance front 36 914mm Appliance side to adjacent sidewall 2 50mm Appliance top to 3 4 19mm trim 10 254mm Mantel 10 254mm deep from appliance top 14 356mm Appliance top to fireplace enclosure top 30 762m...

Страница 16: ...the appliance This fireplace may be elevated off the floor provided it is properly supported by framing materials and maintains ceiling clearances If installed above floor level a solid continuous pla...

Страница 17: ...es on the horizontal pipe must be maintained 3 6 2 2 Vertical Terminations Follow vent pipe manufacturer s installation instructions for vertical terminations Attic insulation shields may be insulated...

Страница 18: ...t installation Rigid pipe dimensions in FIGURE 3 6 reflect Simpson Duravent 5 x 8 coaxial pipe Other manufacturers product dimensions may vary Flexible pipe framing dimensions in FIGURE 3 6 reflect Ko...

Страница 19: ...7 2 Requirements The continuous insulated building envelope and weatherproof FIGURE 3 8 on the following page Fireplace operation is approved from 40 F to 110 F All wiring connections shall be in acco...

Страница 20: ...ted by fireplace installation Free standing structure weatherproof enclosure INSIDE OUTSIDE INSIDE Minimum weatherproof overhang in front and sides M i n i m u m w e a t h e r p r o o f o v e r h a n...

Страница 21: ...arerequiredspecifically for your application or installation FIGURE 3 9 shows removal of the Heat Transfer Kit cover plates There are 2 square cover plates located on the left and the right side of th...

Страница 22: ...this appliance To help avoid or reduce the possibilityofthesheetrocktocrack HussongMfg Co Inc recommends the following methods The front face of the unit to the insulation piece and stand off assembl...

Страница 23: ...EPLACES Non combustible material only Insulation piece MUST rest against non combustible material Non combustible Zone 10 254mm 3 4 19mm Trim 14 356mm 16 406mm 18 457mm 10 254mm 12 305mm 14 356mm 36 9...

Страница 24: ...EPLACES 6 152mm 12 305mm 66 1676mm 36 914mm 12 305mm 9 229mm 6 152mm Non combustible Zone Combustible floor Non combustible material only Insulation piece MUST rest against non combustible material No...

Страница 25: ...FacingandFinishingRequirements SECTION 4 FACING AND FINISHING CAR 46 R 12 February 2022 25 HUSSONG MFG CO INC KOZY HEAT FIREPLACES 66 1676mm 2 50mm unlimited Figure 4 3 Sidewall Clearance...

Страница 26: ...mm 46 1175mm Non combustible material NOTE A 47 x 10 non combustible material board is supplied with the fireplace and allows a 3 4 overlap onto framing sides and 1 2 onto header Screws are allowed to...

Страница 27: ...bottom trim panel with the flange positioned as shown below Insert the tabs on the trim panel into the slots on the bottom opening of the fireplace 3 If installed remove the stand off assembly header...

Страница 28: ...ireplace Raise slightly and push back into position 5 Lower screen front until the notched tabs are firmly in position To remove safety screen lift the screen up and out of slots 4 3 2 Overlap Fit Han...

Страница 29: ...for your installation The louver in the first notch position will match with the first notch position in the notched tabs the louver in the second notch position will match the second notch in the not...

Страница 30: ...valve A listed and Commonwealth of Massachusetts approved 1 2 13mm tee handle manual shut off valve and flexible gas connector are to be connected to the 1 2 13mm control valve inlet If substituting...

Страница 31: ...Feet Meters Flat to 6 12 1 0 0 30 Over 6 12 to 7 12 1 25 0 38 Over 7 12 to 8 12 1 5 0 46 Over 8 12 to 9 12 2 0 0 61 Over 9 12 to 10 12 2 5 0 76 Over 10 12 to 11 12 3 25 0 99 Over 11 12 to 12 12 4 0 1...

Страница 32: ...e 12 30cm 9 23cm K Clearance to mechanical air supply inlet 6 1 83m 3 91cm above if within 10 3m horizontally Massachusetts 10 3m L Clearance above paved sidewalk or paved driveway located on public p...

Страница 33: ...h venting requirements and restrictions as outlined in this manual 7 2 Venting Requirements NOTE Consult the local and national installation codes to assure adequate combustion and ventilation air is...

Страница 34: ...l create the least amount of restriction Closing the baffle restrictor will create more vent exhaust restriction Follow FIGURE 7 1 for restrictor plate installation before attaching venting or through...

Страница 35: ...les located in front of the flue outlet on the top of the fireplace 3 Secure the vertical vent heat shield to the fireplace with 2 attachment screws provided in the components package 7 4 2 Minimum Ho...

Страница 36: ...einstalledforverticalterminations Refer to section 7 4 VENT HEAT SHIELD ASSEMBLY INSTALLATION on page 35 7 5 1 Natural Gas and Propane Vertical Terminations i Minimum Maximum Vertical Terminations 4 1...

Страница 37: ...st be installed when installing minimum vertical rise combination venting Refer to Section 7 4 on page 35 i Minimum 6 Vertical Venting Minimum Maximum Horizontal Termination 6 152mm minimum vertical r...

Страница 38: ...minations must be within the shaded area in FIGURE 7 5 25 7 6m maximum vertical rise 25 7 6m maximum horizontal run 50 15 2m of total length Maximum of 5 90 elbows For each additional 90 elbow used af...

Страница 39: ...be installed when installing minimum vertical rise combination venting Refer to Section 7 4 on page 35 i Minimum 12 Vertical Venting Minimum Maximum Horizontal Termination 12 305mm minimum vertical ri...

Страница 40: ...s must be within the shaded area in FIGURE 7 6 25 7 6m maximum vertical rise 25 7 6m maximum horizontal run 50 15 2m of total length Maximum of 5 90 elbows For each additional 90 elbow used after the...

Страница 41: ...pass through overlapping the heat shields as necessary to accommodate wall thickness The sections must overlap a minimum of 1 1 2 38mm Secure to exterior wall with 4 screws not provided 4 Follow vent...

Страница 42: ...ctrical power from the fireplace before performing this task ATTENTION If converting to propane complete the conversion before installing any light kit components Follow instructions provided with the...

Страница 43: ...ers are located on the bottom of each log Refer to the following instructions and illustrations for proper log placement 1 Position the ember panel in front of the burner 2 Align the holes in the bott...

Страница 44: ...e 10 screws securing the control board Raise the control board to unplug control module and fan wiring from the control module 13 Lift the control board and control module out of the firebox being car...

Страница 45: ...when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 9...

Страница 46: ...n all electric power to the appliance 10 Press the wireless remote POWER button 11 If the appliance will not operate follow the instructions To Turn Off Gas To Appliance and call your service technici...

Страница 47: ...g the UP and DOWN arrows highlight the PILOT icon and press SELECT 3 Use the UP and DOWN arrows to turn the pilot on demand ON or OFF then press SELECT A single beep will be emitted from the control m...

Страница 48: ...by mode if no buttons are pressed within 5 minutes Press the POWER button to reactivate the remote control to ON mode Active functions will be displayed once in ON mode POWER BUTTON MENU BUTTON SELECT...

Страница 49: ...Appliance With the system in the ON position press the remote control POWER button to turn OFF the appliance Functions AUX1 AUX2 and Pilot on Demand can be accessed when the remote control is OFF Onl...

Страница 50: ...s function 1 Press the MENU button to activate the menu 2 Using the UP and DOWN arrows highlight the THERMO icon and press SELECT 3 Use the UP and DOWN arrows to turn the THERMO ON or OFF then press S...

Страница 51: ...the UP and DOWN arrows highlight the AUX1 icon and press SELECT 3 Use the UP and DOWN arrows to adjust to desired light kit intensity The transmission indicator icon will flash and a single beep will...

Страница 52: ...etween the minimum and maximum recommended pressure settings 4 Turn off burner and pilot 5 Disconnect hose and tighten the inlet IN pressure tap by turning screw clockwise Screw should be snug Do not...

Страница 53: ...er will achieve a desired yellow flame but may produce soot on the glass Opening the air shutter will cause a short blue flame that may lift off the burner Slight adjustments to the venturi opening wi...

Страница 54: ...e desired flame appearance 3 Tighten screws after adjustment 4 Reinstall the glass frame assembly and safety barrier 11 2 2 2 Restrictor Plate Installation 1 Remove the safety barrier and the glass fr...

Страница 55: ...c in this manual to determine that all wiring connections are secure and correct Control module selector switch not set properly Verify the ON OFF REMOTE selector switch is ON mode or REMOTE mode Gas...

Страница 56: ...d thermostat operation is turned OFF Pilot and burner extinguish while in operation No propane in tank Check propane tank Refill if necessary Incorrect glass assembly installation Refer to section 8 1...

Страница 57: ...vent system Check the vent pipes for leaks and the vent cap for debris Repair the vent pipes or remove debris from vent cap if necessary No reaction to command Battery back batteries or remote contro...

Страница 58: ...per instructions provided with installation Refer to section 7 0 VENTING on page 33 Performed by Qualified Service Person Frequency Annually Action Examination of the vent system is required The flow...

Страница 59: ...of the flame safety system Pilot or Flame rectification device Visually check pilot light when in operation Inspect and ensure the lighting of the main burner occurs within 4 seconds of the main gas v...

Страница 60: ...exen Conversion Kit Natural Gas DEX 191 1 Propane Dexen PSE IPI Pilot Assembly 700 191 1 LCK C46 D Dexen Conversion Kit Propane DEX RC3 Dexen Transmitter Remote Control C46 035A Burner Tube 700 094 P...

Страница 61: ......

Страница 62: ...This warranty does not cover installation and operational related problems such as environmental conditions nearby trees buildings hilltops mountains inadequate venting or ventilation excessive offset...

Страница 63: ......

Отзывы: