![kozy heat BAY-41-LE Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/kozy-heat/bay-41-le/bay-41-le_installation-and-operation-manual_1999708046.webp)
46
OPERATING INSTRUCTIONS
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#BAY-41-LE R.5 July 2019
10.1.1 Pilot Ignition Selection (IPI/CPI)
Model #BAY-41-LE (electronic ignition system) has the option of a
continuous (standing) pilot. This features allows the system to change
from a intermittent pilot ignition (IPI) system to a continuous pilot
ignition (CPI) system. The standing (or continuous) pilot will keep the
firebox warm and establish a draft in the vent, which allows the main
burner to ignite with less air-flow disruption.
There are (2) rocker switches located on the gas valve housing in the
control compartment. The main burner rocker switch is marked ‘B’ and
the IPI/CPI pilot rocker switch is marked ‘P’. See in Figure 10.1.
•
For intermittent pilot mode (IPI), set the IPI/CPI rocker switch
to OFF. The pilot and main burner will ignite and turn off
automatically when this IPI/CPI rocker switch is set to OFF.
•
For continuous pilot mode (CPI), set the IPI/CPI rocker switch to
ON. This will ignite the pilot only. The pilot will remain lit when the
main burner ON/OFF rocker switch is pressed to OFF.
HI/LO PRESSURE
MODULATOR KNOB
Figure 10.1, Rocker Switch Locations
10.1.2 Flame Height and Heat Output Adjustment
Model #BAY-41-LE (electronic ignition system) is equipped with a
manual HI/LO pressure modulator knob for adjusting main burner
flame height and the heat output of the fireplace.
•
Open the control compartment access panel to access the gas
valve and the HI/LO pressure regulator knob.
•
To adjust, turn the HI/LO knob counterclockwise to LO position
or clockwise to HI position, until desired flame appearance and
heat output is achieved.
Figure 10.2, HI/LO Pressure Regulator Knob