#BAY-41-LE R.5 July 2019
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
FRAMING
13
3.5 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-offs
0 in
0 mm
From appliance left and right side stand-offs
0 in
0 mm
From appliance back stand-offs
0 in
0 mm
From appliance corners
1/4 in
6 mm
From appliance front
36 in
914 mm
From appliance top to ceiling
31 in
787 mm
Appliance sides to adjacent sidewall
1 in
25 mm
Top of appliance to 3/4 in (19 mm) trim
5-1/2 in
139 mm
Mantel 6 in (152 mm) deep from appliance top
9 in
356 mm
1”
(25mm)
28¼”
(717mm)*
41¼”
(1048mm)
17
½
”
(445mm)
41
¼
”
(1048mm)
½
”
(13mm)
41
¼
”
(1048mm)
56
5⁄16
”
(1431mm)
28
3⁄16
”
(716mm)
¼
”
(6mm)
39
13⁄16
”
(1012mm)
13”
(331mm)
17
½
”
(445mm)
41
¼
”
(1048mm)
½
”
(13mm)
½
”
(13mm)
17
½
”
(445mm)
41
¼
”
(1048mm)
TYPICAL VERTICAL INSTALLATION
TOP VENT
TYPICAL HORIZONTAL INSTALLATION
TOP VENT
TYPICAL HORIZONTAL INSTALLATION
REAR VENT
TYPICAL VERTICAL INSTALLATION
REAR VENT
TYPICAL CORNER INSTALLATION
TOP VENT
*DIMENSION SHOWN WITH LISTED DURAVENT ELBOW.
NOTE: Approved vent system elbows for this appliance vary in vertical
length. Consult vent manufacturer’s instructions to determine the
elbow dimension used for your installation. Adjust as necessary to
maintain the required 1” (25mm) clearance from the vent pipe to
combustible material.