![Kozlusan Propel 25 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/kozlusan/propel-25/propel-25_owners-manual_1999610019.webp)
19 |
P a g e
TROUBLESHOOTING
FAILURE
CAUSE
REMEDY
Burner creaks
Burner is new (wait)
Chimney is sweating
Poor insulation
Insulate the chimney well
Low exhaust temperature
Increase the minimum power/ the boiler
temp.. , it may be necessary to restore the
chimney
Pellet boiler is sweating
Check return flow increase at external
control
Heating circuits do not work/
Heating system is slow to heat up
The boiler is on utility water operation mode
Change operating mode
Hydraulic problem
Contact installer
Altered heating curve
Adjust
Heating circuit pump is defect
>Inform customer service
Air in the system
Bleed air from system
Pumps run on wrong ration speed
>Inform customer service
High temperature value on screen
No water in boiler
Fill the system with sufficient water
Circulation pump is not working
Active/Inform customer service
Air in the system /boiler
Remove /emliminate/Inform customer
service
Defective boiler temperature sensor
>Inform customer service