42
7.2.3. Installation Angle Requirement
Never install the inverter horizontally, or with a forward tilt or with a backward tilt or even with
upside down. The horizontal installation can result in damage to the inverter.
7.2.4 Installation Clearance Requirements
Reserve enough clearance around the inverter to ensure sufficient space for heat dissipation.
Clearance requirement
:
7.2.5 Mounting the Inverter
Remember that this inverter is heavy! Please be careful when lifting out from the package.
-The inverter is suitable for mounting on concrete or other non-combustible surface only.
-The maximum load bearing of the carrier must be greater than or equal to four times the weight
of the inverter.