![Koyoe KY-EST06KH Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/koyoe/ky-est06kh/ky-est06kh_user-manual_1999590021.webp)
21
Label
Description
Caution
Failing to observe a warning indicated in this manual may result in injury.
Danger of high voltage and electric shock!
Danger of hot surface!
Components of the product can be recycled.
This side up! The package must always be transported, handled and stored in
such a way that the arrows always point upwards.
No more than six (6) identical packages being stacked on each other.
Product should not be disposed as household waste.
The package/product should be handled carefully and never be tipped over or
slung.
Refer to the operating instructions.
Keep dry! The package/product must be protected from excessive humidity and
must be stored under cover.
Inverter will be touchable or operable after minimum 10 minutes of being
turned off or totally disconnected, in case of any electrical shock or injury
.
CE Mark.
Attention!
1. When connecting the input and output of the inverter, it is necessary to connect the ground wire of the inverter first, and
then connect the DC input and AC output. When disconnecting the inverter wiring, the inverter ground wire must be finally
disconnected.
2. Need permission from the local utility prior to connecting the inverter to the utility grid and hire qualified personnel.
3. Observe all documentation that accompanies the inverter.
4. Installations maintenance and installed should be carried out by competent persons, who have sufficient skills and training
to apply safe methods of work to install.
5. There is no maintainable part in the inverter. If there is any problem, it must be maintained by professionals.
6. All electrical installations must be done in accordance with the National Wiring Rules of Standard and local code 62109.
7. Non-isolated inverters : the PV modules should have an IEC61730 Class A rating.
8. Inverters may be over 20kg. Please be careful when handling and lifting. Equipment or parts weighing more than 18 kg shall
be equipped with lifting and handling tools or as indicated in the manufacturer's documentation.
9. Software version information can be read by LCD or the upper computer software.
10. The inverter is non-isolated between DC input and AC output. Product identification must be clearly visible after
installation.
-Risk of Electric Shock, Do Not Remove Cover. No User Serviceable Parts Inside. Refer Servicing To Qualified Service
Personnel.
-When the photovoltaic array is exposed to light, it supplies a dc voltage to this equipment.
-Please note that PV input voltage must be less than 1000V . Too high voltage could cause damage to the inverter.
11. Please avoid direct sunlight to the inverter.
12. When the inductive load of the electric model is connected to the off-grid port, please note that the instantaneous peak
current of load starting shall not be greater than two times of the RMS current of different models
(
6KW-206A,8KW-
24A,10KW-30A,12KW-36A,15KW-44A,17KW-50A,20KW-62A
)
.
Содержание KY-EST06KH
Страница 1: ...1 User Manual 3 Phase Hybrid Inverter KY EST06KH KY EST20KH V1 0...
Страница 10: ...10 Dimensions KY EST06 10KH unit mm Dimensions KY EST12 20KH unit mm...
Страница 12: ...12 Fig1 5 Three phase Meter Dimension unit mm...
Страница 15: ...15 Each successive press of the button selects a new parameter...
Страница 16: ...16 Each successive press of the button selects a new parameter...
Страница 17: ...17 Each successive press of the button selects a new parameter...
Страница 32: ...32 View the power quality response mode...
Страница 34: ...34 Figure 5 2 2...
Страница 48: ...48 Neutral line of alternative supply must be disconnected after the grid is off applies to other counties...
Страница 68: ...68...
Страница 70: ...70 Figure...
Страница 73: ...73 Fig 9 1 LCD operating figure...