Cautions
Specifications
Model No.
Indication
Lever Design
Dimensions
External
Dimensions
Accessories
Performance
Curve
Lever Installation/
Removal Procedure
model
BZL
Control Valve
Speed Control Valve (For Low Pressure)
Controlled Flow Direction
0
2
4
6
8
10
1
0
2
3
4
←Closed Number of Turns of Adjusting Screw Opened→
Flow Rate (L/min)
Free Flowing Direction
0
2
4
6
8
10
1
0
2
3
4
5
6
Pressure Loss (MPa)
Flow Rate (L/min)
BZL0100-B:Meter-out
Pressure Loss 5MPa
Pressure Loss 1MPa
Pressure Loss 3MPa
Fully Closed
Fully Opened
Flow Rate Characteristic Graph < Hydraulic Fluids ISO-VG32(25〜35°)>
External Dimensions
Machine Dimensions of Mounting Area
Notes
1. Please read "Speed control circuit of hydraulic cylinder and notes" to assist with proper hydraulic circuit design.
If there is something wrong with the circuit design, it leads to the applications malfunction and damage. (Refer to page 17)
2. It is dangerous to air bleed during operation under high pressure. It must be done under lower pressure.
(For reference: the minimum operating range of the product within the circuit.)
Model No. Indication (Speed Control Valve for Low Pressure)
Specifications
Applicable Product
1
2
3
BZL 0 10 0 - B
2
1
G Thread Size
10
: Thread Part G1/8A Thread
20
: Thread Part G1/4A Thread
0
: Revision Number
Design No.
3
Control Method
B
: Meter-out
LHA-A
Swing Clamp Quick Change Lever Type A
LHA0360-A
LHA0400-A
LHA0480-A
LHA0550-A
LHA0650-A
LHA0750-A
Model No.
BZL0100-B
BZL0200-B
Thread Part
MPa
MPa
MPa
mm
2
℃
N・m
BZL0100-B
G1/8A
2.6
10
7
10.5
Meter-out
0.12
General Hydraulic Oil Equivalent to ISO-VG-32
0 〜 70
BZL0200-B
G1/4A
5.0
25
Model No.
Maximum Operating Pressure
Withstanding Pressure
Control Method
G Thread Size
Cracking Pressure
Maximum Passage Area
Usable Fluid
Operating Temperature
Recommended Tightening Torque for Main Body
Notes: 1. Minimum passage area when control side is fully opened is same as the maximum passage area in the table above.
2. It must be mounted with recommended torque. If mounting torque is insufficient,
the flow control valve may not be able to adjust the flow rate because of the metal seal structure.
3. Do not attach a used BZL to other clamps.
Flow control may not be done because the bottom depth difference of G thread makes metal sealing insufficient.
Notes: 1. Flow control circuit for double acting cylinder should have meter-out circuits for both the lock and release sides.
Meter-in control may have adverse effect by presence of air in the system.
Controlled Flow Direction
0
5
10
15
20
25
1
0
2
3
4
←Closed Number of Turns of Adjusting Screw Opened→
Flow Rate (L/min)
Free Flowing Direction
0
5
10
15
20
25
1
0
2
3
4
5
6
Pressure Loss (MPa)
Flow Rate (L/min)
BZL0200-B:Meter-out
Pressure Loss 5MPa
Pressure Loss 1MPa
Pressure Loss 3MPa
Fully Closed
Fully Opened
0.2
45
°
0.4
φ
T
max.
φ
S
min.
φ
R
φ
V
Q
P1 Port
Hydraulic Pressure
Supply Side
φ
W
P2 Port
Clamp Side
U Thread
(Prepared Hole
φ
T
Flat Bottom)
min.P
N
Z
Z
⊥ 0.1
0
- 0.10
Model No.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R (Flat Surface Area)
S
T
U
V
W
BZL0100-B
BZL0200-B
14
18
15.5
20
15
16
12
13
8.5
9.5
(11.6)
(15.1)
G1/8A
G1/4A
3
3
3.5
3.5
10
10
3
3
M6×0.75
M6×0.75
11.5
15
8.5
11
※1
9
11.5
16
20.5
10
13.5
8.7
11.5
G1/8
G1/4
2 〜 3
3 〜 4
2.5 〜 5
3.5 〜 7
(mm)
Adjusting Screw
BZL0
□
00
-B
(Clamp)
G Thread
Exclusive Packing
(Included)
P2 Port
Clamp Side
P1 Port
Hydraulic Pressure
Supply Side
F
max.H
max.C
D
E
J
φ
B
Hex. Socket
L
M Screw
Hexagon K
Hexagon A
P1 Port
Hyd. Pressure
Supply Side
P2 port
Clamp side
Circuit Symbol:Meter-out
B
OPEN
CLOSE
Notes:
1. Since the area is sealing part, be careful not to damage it.
2. Since the area is the metal sealing part of BZL, be careful
not to damage it. (Especially when deburring)
3. No cutting chips or burr should be at the tolerance part of
machining hole.
4. As shown in the drawing, P1 port is used as the hydraulic supply
and P2 port as the clamp side.
5. If mounting plugs or fittings with G thread specification available
in the market, the dimension '※1' should be 12.5.
Attention
14
13