Cautions
Specifications
Model No.
Indication
Lever Design
Dimensions
External
Dimensions
Accessories
Performance
Curve
Lever Installation/
Removal Procedure
model
LHA-A
Swing Clamp
Quick Change Lever Type A
Clamping Force Curve
0
1
7
6
5
4
3
2
8
0
1
2
3
4
5
6
7
Supply Hydraulic Pressure (MPa)
Clamping Force (
kN)
L=200(s=170)
L=140(s=110)
L=80(s=50)
L=50(s=20)
Cylinder Force
L=150(s=127.5)
L=100(s=77.5)
L=60(s=37.5)
L=40(s=17.5)
Cylinder Force
0
0.5
1
1.5
2.5
2
3
3.5
0
1
2
3
4
5
6
7
Supply Hydraulic Pressure (MPa)
Clamping Force (
kN)
L=200(s=174.5)
L=140(s=114.5)
L=80(s=54.5)
L=50(s=24.5)
Cylinder Force
Non-Usable Range (
■
)
Non-Usable Range (
■
)
Non-Usable Range (
■
)
0
1
2
3
4
5
0
1
2
3
4
5
6
7
Supply Hydraulic Pressure (MPa)
Clamping Force (
kN)
Cylinder Force
Clamping Force (kN) Non-Usable Range(
■
) Max. Lever Length
(kN)
Lever Length L (mm)
(L)
L=50 L=60 L=80 L=100 L=120 L=140 L=160 L=200 (mm)
7
4.87
4.3
4.2
4.0
3.9
3.7
3.6
141
6.5
4.52
4.0
3.9
3.7
3.6
3.4
3.3
157
6
4.17
3.7
3.6
3.5
3.3
3.2
3.1
2.9
178
5.5
3.82
3.4
3.3
3.2
3.0
2.9
2.8
2.7
2.5
204
5
3.48
3.1
3.0
2.9
2.8
2.7
2.6
2.5
2.3
230
4.5
3.13
2.8
2.7
2.6
2.5
2.4
2.3
2.2
2.0
230
4
2.78
2.5
2.4
2.3
2.2
2.1
2.1
2.0
1.8
230
3.5
2.43
2.2
2.1
2.0
2.0
1.9
1.8
1.7
1.6
230
3
2.09
1.9
1.8
1.7
1.7
1.6
1.6
1.5
1.4
230
2.5
1.74
1.6
1.5
1.5
1.4
1.4
1.3
1.2
1.2
230
2
1.39
1.3
1.2
1.2
1.1
1.1
1.0
1.0
0.9
230
1.5
1.04
1.0
0.9
0.9
0.9
0.8
0.8
0.8
0.7
230
Max. Operating Pressure (MPa) 7.0
7.0
7.0
7.0
7.0
7.0
6.6
5.7
Cylinder Force
Clamping Force (kN) Non-Usable Range(
■
) Max. Lever Length
(kN)
Lever Length L (mm)
(L)
L=40 L=50 L=60 L=70 L=80 L=100 L=120 L=150 (mm)
7
3.50
3.0
2.9
2.8
2.7
2.6
2.4
2.2
124
6.5
3.25
2.7
2.7
2.6
2.5
2.4
2.2
2.1
144
6
3.00
2.5
2.5
2.4
2.3
2.2
2.1
1.9
1.7
171
5.5
2.75
2.3
2.3
2.2
2.1
2.0
1.9
1.8
1.6
210
5
2.50
2.1
2.1
2.0
1.9
1.9
1.7
1.6
1.5
210
4.5
2.25
1.9
1.9
1.8
1.7
1.7
1.6
1.5
1.3
210
4
2.00
1.7
1.7
1.6
1.5
1.5
1.4
1.3
1.2
210
3.5
1.75
1.5
1.4
1.4
1.4
1.3
1.2
1.1
1.0
210
3
1.50
1.3
1.2
1.2
1.2
1.1
1.1
1.0
0.9
210
2.5
1.25
1.1
1.0
1.0
1.0
0.9
0.9
0.8
0.8
210
2
1.00
0.9
0.8
0.8
0.8
0.8
0.7
0.7
0.6
210
1.5
0.75
0.7
0.6
0.6
0.6
0.6
0.6
0.5
0.5
210
Max. Operating Pressure (MPa) 7.0
7.0
7.0
7.0
7.0
7.0
7.0
6.4
Cylinder Force
Clamping Force (kN) Non-Usable Range(
■
) Max. Lever Length
(kN)
Lever Length L (mm)
(L)
L=50 L=60 L=80 L=100 L=120 L=140 L=160 L=200 (mm)
7
7.21
6.3
6.2
5.9
5.6
5.4
5.2
142
6.5
6.69
5.8
5.7
5.5
5.2
5.0
4.8
159
6
6.18
5.4
5.3
5.1
4.8
4.6
4.4
4.2
180
5.5
5.66
5.0
4.8
4.6
4.4
4.2
4.1
3.9
3.6
209
5
5.15
4.5
4.4
4.2
4.0
3.9
3.7
3.5
3.2
245
4.5
4.63
4.1
4.0
3.8
3.6
3.5
3.3
3.2
2.9
245
4
4.12
3.6
3.5
3.4
3.2
3.1
3.0
2.8
2.6
245
3.5
3.60
3.2
3.1
3.0
2.8
2.7
2.6
2.5
2.3
245
3
3.09
2.7
2.7
2.6
2.4
2.3
2.2
2.1
2.0
245
2.5
2.57
2.3
2.2
2.1
2.0
2.0
1.9
1.8
1.6
245
2
2.06
1.8
1.8
1.7
1.6
1.6
1.5
1.4
1.3
245
1.5
1.54
1.4
1.4
1.3
1.2
1.2
1.1
1.1
1.0
245
Max. Operating Pressure (MPa) 7.0
7.0
7.0
7.0
7.0
7.0
6.4
5.6
LHA0400-A
LHA0480-A
LHA0550-A
F
=
P(1-0.0016×L)
/
( 2.0920+0.0040×L)
F
=
P(1-0.0009×L)
/
( 1.4892+0.0018×L)
F
=
P(1-0.0011×L)
/
( 1.0039+0.0011×L)
s
0
1
7
6
5
4
3
2
10
9
8
0
1
2
3
4
5
6
7
Supply Hydraulic Pressure (MPa)
Clamping Force (
kN)
Cylinder Force
L=50(s=15)
L=80(s=45)
L=140(s=105)
L=200(s=165)
Non-Usable Range (
■
)
Cylinder Force
Clamping Force (kN) Non-Usable Range(
■
) Max. Lever Length
(kN)
Lever Length L (mm)
(L)
L=50 L=60 L=80 L=100 L=120 L=140 L=160 L=200 (mm)
7
9.35
8.1
7.9
7.6
7.3
115
6.5
8.68
7.5
7.3
7.0
6.7
6.5
127
6
8.02
6.9
6.8
6.5
6.2
6.0
5.7
142
5.5
7.35
6.4
6.2
6.0
5.7
5.5
5.3
5.0
161
5
6.68
5.8
5.7
5.4
5.2
5.0
4.8
4.6
187
4.5
6.01
5.2
5.1
4.9
4.7
4.5
4.3
4.1
3.8
221
4
5.34
4.6
4.5
4.4
4.2
4.0
3.8
3.7
3.4
260
3.5
4.68
4.1
4.0
3.8
3.7
3.5
3.4
3.2
3.0
260
3
4.01
3.5
3.4
3.3
3.1
3.0
2.9
2.8
2.5
260
2.5
3.34
2.9
2.9
2.7
2.6
2.5
2.4
2.3
2.1
260
2
2.67
2.3
2.3
2.2
2.1
2.0
1.9
1.9
1.7
260
1.5
2.00
1.8
1.7
1.7
1.6
1.5
1.5
1.4
1.3
260
Max. Operating Pressure (MPa) 7.0
7.0
7.0
7.0
6.8
6.1
5.6
4.8
LHA0650-A
F
=
P(1-0.0009×L)
/
( 0.7822+0.0010×L)
0
2
12
10
8
6
4
14
0
1
2
3
4
5
6
7
Supply Hydraulic Pressure (MPa)
Clamping Force (
kN)
Cylinder Force
L=50(s=10)
L=80(s=40)
L=140(s=100)
L=200(s=160)
Non-Usable Range (
■
)
Cylinder Force
Clamping Force (kN) Non-Usable Range(
■
) Max. Lever Length
(kN)
Lever Length L (mm)
(L)
L=50 L=60 L=80 L=100 L=120 L=140 L=160 L=200 (mm)
7
14.21
12.4 12.2 11.7 11.3 10.9 10.5
147
6.5
13.19
11.5 11.3 10.9 10.5 10.2
9.8
9.5
163
6
12.18
10.6 10.4 10.1
9.7
9.4
9.0
8.7
184
5.5
11.16
9.7
9.6
9.2
8.9
8.6
8.3
8.0
7.5
209
5
10.15
8.9
8.7
8.4
8.1
7.8
7.5
7.3
6.8
244
4.5
9.13
8.0
7.8
7.6
7.3
7.0
6.8
6.6
6.1
280
4
8.12
7.1
7.0
6.7
6.5
6.3
6.0
5.8
5.4
280
3.5
7.10
6.2
6.1
5.9
5.7
5.5
5.3
5.1
4.8
280
3
6.09
5.3
5.2
5.1
4.9
4.7
4.5
4.4
4.1
280
2.5
5.07
4.5
4.4
4.2
4.1
3.9
3.8
3.7
3.4
280
2
4.06
3.6
3.5
3.4
3.3
3.2
3.0
2.9
2.7
280
1.5
3.04
2.7
2.6
2.5
2.5
2.4
2.3
2.2
2.1
280
Max. Operating Pressure (MPa) 7.0
7.0
7.0
7.0
7.0
7.0
6.9
5.9
LHA0750-A
F
=
P(1-0.0007×L)
/
( 0.5175+0.0006×L)
Cylinder Force
L=150(s=130)
L=100(s=80)
L=50(s=30)
L=30(s=10)
0
0.5
1
1.5
2
2.5
0
1
2
3
4
5
6
7
Supply Hydraulic Pressure (MPa)
Clamping Force (
kN)
Cylinder Force
Clamping Force (kN) Non-Usable Range(
■
) Max. Lever Length
(kN)
Lever Length L (mm)
(L)
L=30 L=40 L=50 L=60 L=80 L=100 L=120 L=150 (mm)
7
2.48
2.2
2.1
2.0
1.9
1.8
96
6.5
2.30
2.0
1.9
1.9
1.8
1.7
1.5
110
6
2.13
1.9
1.8
1.7
1.7
1.5
1.4
1.3
129
5.5
1.95
1.7
1.6
1.6
1.5
1.4
1.3
1.2
1.1
150
5
1.77
1.6
1.5
1.4
1.4
1.3
1.2
1.1
1.0
150
4.5
1.59
1.4
1.4
1.3
1.3
1.2
1.1
1.0
0.9
150
4
1.42
1.3
1.2
1.2
1.1
1.0
1.0
0.9
0.8
150
3.5
1.24
1.1
1.1
1.0
1.0
0.9
0.8
0.8
0.7
150
3
1.06
1.0
0.9
0.9
0.9
0.8
0.7
0.7
0.6
150
2.5
0.89
0.8
0.8
0.7
0.7
0.7
0.6
0.6
0.5
150
2
0.71
0.7
0.6
0.6
0.6
0.5
0.5
0.5
0.4
150
1.5
0.53
0.5
0.5
0.5
0.4
0.4
0.4
0.4
0.3
150
Max. Operating Pressure (MPa) 7.0
7.0
7.0
7.0
7.0
6.9
6.3
5.6
LHA0360-A
F
=
P(1-0.0021×L)
/
( 2.9379+0.0052×L)
Clamping Force Calculation Formula (kN)
※1
Non-Usable Range (
■
)
F:Clamping Force (kN)
P:Hydraulic Pressure (MPa)
Hydraulic
Pressure
(MPa)
Clamping Force Calculation Formula (kN)
※1
Hydraulic
Pressure
(MPa)
Clamping Force Calculation Formula (kN)
※1
Hydraulic
Pressure
(MPa)
Clamping Force Calculation Formula (kN)
※1
Hydraulic
Pressure
(MPa)
Clamping Force Calculation Formula (kN)
※1
Hydraulic
Pressure
(MPa)
Clamping Force Calculation Formula (kN)
※1
Hydraulic
Pressure
(MPa)
(Example) When using LHA0480-A
Supply Hydraulic Pressure 5.0MPa, Lever Length L=50mm,
Clamping force is about 3.1kN.
L : Lever Length (mm)
Notes:
1. Tables and graphs shown are the relationships between the clamping force (kN) and supply hydraulic pressure (MPa).
2. Cylinder output (when L=0) cannot be calculated with the formula of clamping force.
3. There may be no lever swing action with large inertia depending on supply hydraulic pressure or lever mounting position.
4. The clamping force is shown with lever in the locked position.
5. The clamping force varies depending on the lever length. Set the supply hydraulic pressure suitable to the lever length.
6. Using in the non-usable range may damage the clamp and lead to fluid leakage.
7. The tables and graphs are only for reference. The exact results should be calculated based on the clamping force calculation formula.
※1. F : Clamping Force (kN), P : Supply Hydraulic Pressure (MPa), L : Lever Length (mm).
※ Clamping force curve is the same as that of standard model LHA.
6
5