OPERATING  INSTRUCTIONS

• 

Water Entering:

 After fixing all the pipes, then make

 the cold and hot water-blending valve rotate to 
the high temperature sector according to the 
clockwise direction. And reopen the cold 
water pipe's water entering valve. At this time, 
the electrical water heater's tank will start to enter 
the water. Waiting that the shower sector of the 
water exiting mouth is in normal condition, 
which indicates that the tank has full filled with water

 

Cautions:

 During  the electrical  water heater  is in the normal  operating 

procedures,  the  water-entering  valve  of  the  cold  water  pipe's  mouth-
entering sector must be in the open condition from the beginning to the 
end. At this time, the water-entering valve can still make the functions of 
regulating  the  water-existing  mouth  section's  flowing  strength  and 
weakness. However, the cold and hot mixed water valve can only regulate 
the water temperatures and make the function of closing the water exiting.

• 

Plug into the Power Source:

 After confirming the tank to be fully filled the 

water,  you  can  make  the  power  source's  plug  into  the  outlet  and  put 
through the power sources.

• 

Hot water operations:

 After the electrical water heater normally works 

and the heats for a long period of time, you can use the hot water in the 
tank,  you  need  to  make  the  cold  and  hot  mixed  valve  rotate  with  the 
clockwise  direction  slowly  from  the  low  temperature  to  the  high 
temperatures  in  the  closed  condition.  And  adjust  it  to  your  proper 
temperature. At that time, the shower mouth can come out the hot water. 
After finishing the uses, you can turn it to the closed section by the anti-
clockwise direction and shut off the mixed water valve.

 

Cautions:

  When  adjusting  the  water  temperature  of  the  water-exiting 

mouth, you don't make the shower directly to the human body; you should 
test the water temperature first to avoid burning to damages.

• 

Overheating  Protections:

  Under  the  condition  of  putting  through  the 

power, but the heating pipe won't heat from the beginning to the end. That 
means  the  two  power-selecting  switch  will  be  in  the  putting  through 
position. At this time, it may appear the over heat protections (that is to 
make  functions  by  the  double-positional  temperature-limiting  protection 
switch).

Содержание KWHZF15Y

Страница 1: ...KWHZF15Y KWHZF25Y Read this instruction manually and preserve the manual for future reference User s Manual Storage Water Heater...

Страница 2: ...ty Characteristics 5 Technical parameter 6 Product Structure 6 Assembling Instructions 7 Pipe Connections 7 Caution 7 Operating Instructions 9 Operating Guides 10 Daily And Common Maintenance 10 Elect...

Страница 3: ...heater is fully filled with water first After that you can put through the power source When no tap water provides you mustn t use the water in the tank of electrical water heater For the cold and fro...

Страница 4: ...which indicates the water temperature in the tank is still over high Please open the water exiting valve and pour out the heat water for several minutes then repeat the above mentioned procedures aft...

Страница 5: ...entilating styled security valve its pressure leakage exit sector may not exit the water drops to drip down Otherwise during the heating procedure the water entering pipe s outer cover under the safet...

Страница 6: ...PARAMETER PRODUCT STRUCTURE Rated Voltage 230V Rated Power 2000W Rated Frequenc 50Hz Rated Current 8 7A Rated Pressure 0 8MPa Rated volume 15L 25L Rated Water 75 C Heating Efficiency 90 Temperature Wa...

Страница 7: ...pace to maintain when it is necessary Assembling Method After selecting the proper positions well use the fitted inflation bolts to fix the hanging board firmly and then hang on the electrical water h...

Страница 8: ...r Pipe Mono directional Security Valve Hand rinsing Basin Tap Water Pipe Water Inlet Valve Mixed Water Valve Pressure leakage Pipe Cold Water Inlet Hot Water Outlet Machine Body 8 fitted the qualified...

Страница 9: ...o be fully filled the water you can make the power source s plug into the outlet and put through the power sources Hot water operations After the electrical water heater normally works and the heats f...

Страница 10: ...lockwise direction You can select to use the heating temperatures without grades in the temperature ranges of twenty to seventy five degrees Celsius from closing to the low medium and high bands or fr...

Страница 11: ...temperature to be high Consult service technician Consult service technician 1 No power or inappropriate contact 1 Dificient heating time 1 Halting the tap water 1 The various pipe mouth s connection...

Страница 12: ...make every effort to carry out repairs replacement of parts components under this Warranty expeditiously In the event of any delay in service due to lack non availability of spare parts component the...

Страница 13: ...ced or altered g Any alterations are made in the electrical circuit or parts components either by way of adjustments addition removal alteration by the customer and or any unauthorised person s h If t...

Страница 14: ...53 First Floor Shakarpur Vikas Marg Delhi 92 Ph 011 22469856 Mob 09873601702 DELHI 01 Cure Well Electronics Pvt Ltd Mb 167a Gali No 4 Shakarpur Near Agarwal Dharamsala Delhi 91 Ph 011 22443083 224683...

Страница 15: ...94 9388888245 PANIPAT Alfa Service Shop No 1 125 Sukhdev Nagar Panipat 132 103 Haryana Ph 0180 4006044 Mob 98130 72804 PATNA Kool Craft 130 E S K Puri Boring Road Patna 800001 Ph 0612 3298766 98352367...

Страница 16: ...Piece 1 Electric Water Heater 1 2 Operation Handbook 1 3 Inflation Bolt 2 4 Security Valve 1 Imported Marketed by Future Value Retail Limited Tower C 8th Floor 247 Park L B S Marg Vikhroli West Mumbai...

Отзывы: