Firm Cement Wall
Inflation Bolt
Diagram 5
7
ASSEMBLING INSTRUCTIONS
PIPE CONNECTIONS
CAUTIONS ITEMS
• This electrical water heater should be mounted on the solid cement walls
and at a place which is closer to the power source socket.
Caution:
Please try to use our company's fitted accessories to mount this
electrical water heater. After confirming the brackets to be firmly fixed for
the reliabilities , then you can hang on this electrical water heater.
Otherwise, the electrical water heater may fall down from the walls, and
cause the severe damaging accidents.
• Before determining the bolt hole's position, you should guarantee the right
side of the electrical water heater to be more than 200mm away the
ground. This will be convenient to leave out a certain space to maintain
when it is necessary.
• Assembling Method: After selecting the
proper positions well, use the fitted
inflation bolts to fix the hanging board
firmly, and then hang on the electrical
water heater (Diagram 5)
• All the pipe parts are G1/2. Wind a certain raw material tape at the water-
entering mouth sector of the electrical water heater (Blue Sign
Identification) Then re-install the mono-directional security valve well.
• The remaining pipe's connection method can be referred to No.7 figure
(Diagram 6).
• If the user want to offer the water by poly-routes, then you can refer to the
No. 8 figure for connecting the pipes (Diagram 7).
• The installed walls must be solid; the inflation bolts must be tightly spun.
And install it firmly. Mustn't loosen and prohibit to mount it in the heart-
emptied bricks or the brick crevices.
• The power source's socket must be adopted the super-quality mono-
phase tri-pole one .which complies with the state's ganges, and it must be