SNMP Commands
4-73
4
•
version
- Specifies whether to send notifications as SNMP Version 1, 2c or
3 traps. (Range: 1, 2c, 3; Default: 1)
-
auth
|
noauth
|
priv
- This group uses SNMPv3 with authentication, no
authentication, or with authentication and privacy. See “Simple Network
Management Protocol” on page 3-39 for further information about these
authentication and encryption options.
•
port
- Host UDP port to use. (Range: 1-65535; Default: 162)
Default Setting
• Host Address: None
• Notification Type: Traps
• SNMP Version: 1
• UDP Port: 162
Command Mode
Global Configuration
Command Usage
• If you do not enter an
snmp-server host
command, no notifications are sent.
In order to configure the switch to send SNMP notifications, you must enter at
least one
snmp-server host
command. In order to enable multiple hosts, you
must issue a separate
snmp-server host
command for each host.
• The
snmp-server host
command is used in conjunction with the
snmp-server enable traps
command. Use the
snmp-server enable traps
command to enable the sending of traps or informs and to specify which
SNMP notifications are sent globally. For a host to receive notifications, at
least one
snmp-server enable traps
command and the
snmp-server host
command for that host must be enabled.
• Some notification types cannot be controlled with the
snmp-server enable
traps
command. For example, some notification types are always enabled.
• Notifications are issued by the switch as trap messages by default. The
recipient of a trap message does not send a response to the switch. Traps are
therefore not as reliable as inform messages, which include a request for
acknowledgement of receipt. Informs can be used to ensure that critical
information is received by the host. However, note that informs consume more
system resources because they must be kept in memory until a response is
received. Informs also add to network traffic. You should consider these
effects when deciding whether to issue notifications as traps or informs.
To send an inform to a SNMPv2c host, complete these steps:
1. Enable the SNMP agent (page 4-68).
2. Allow the switch to send SNMP traps; i.e., notifications (page 4-74).
3. Specify the target host that will receive inform messages with the
snmp-server host
command as described in this section.
4. Create a view with the required notification messages (page 4-77).
5. Create a group that includes the required notify view (page 4-79).
Содержание JetNet 5228G Series
Страница 3: ...www edge core com 2 24FE 4G Layer 2 4 Ethernet Switch Management Guide V1 1...
Страница 24: ...Tables xx...
Страница 310: ...Configuring the Switch 3 264 3...
Страница 636: ...Command Line Interface 4 326 4...
Страница 650: ...Glossary Glossary 8...
Страница 656: ...Index 6 Index...
Страница 657: ......
Страница 658: ......