background image

 

                                       

 

JetLink 1102/

 

JetLink 1302 User Manual

 

 

Korenix JetLink 1102 

Industrial Modbus RTU/TCP to EtherNet/IP 

Fieldbus Gateway, -10~60

 

 

Korenix JetLink 1302 

Industrial Modbus RTU/TCP to PROFINET 

Fieldbus Gateway, -10~60

 

User Manual 

  Ver. 01, Oct-2018 

Firmware V1.0 

 

 

 

  

www.korenix.com

 

Содержание JetLink 1102

Страница 1: ...anual 1 Korenix JetLink 1102 Industrial Modbus RTU TCP to EtherNet IP Fieldbus Gateway 10 60 Korenix JetLink 1302 Industrial Modbus RTU TCP to PROFINET Fieldbus Gateway 10 60 User Manual Ver 01 Oct 20...

Страница 2: ...to EtherNet IP Fieldbus Gateway 10 60 Korenix JetLink 1302 Industrial Modbus RTU TCP to PROFINET Fieldbus Gateway 10 60 User s Manual Copyright Notice Copyright 2018 Korenix Technology Co Ltd All rig...

Страница 3: ...acement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem enco...

Страница 4: ...is equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera...

Страница 5: ...lent type recommended by the man ufacturer Discard used batteries according to the manufacturer s instructions Note Notes provide optional additional information Document Feedback To assist us in maki...

Страница 6: ...t step on it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to av...

Страница 7: ...tion period The following guidelines are also recommended Wear a grounded wrist or ankle strap and use gloves to prevent direct contact to the device before servicing the device Avoid nylon gloves or...

Страница 8: ...GATEWAY 19 2 3 1 DIN Rail Mounting 19 2 3 1 1 Installing the DIN Rail Mounting Kit 19 2 3 1 2 Removing the DIN Rail Mounting Kit 21 2 3 2 Wall Mounting 22 2 4 CONNECTING THE FIELDBUS GATEWAY TO ETHERN...

Страница 9: ...IP Setting 39 3 4 SERIAL SETTINGS 42 3 4 1 Port 42 3 5 PROTOCOL SETTING 43 3 5 1 EtherNet IP Setting 43 3 5 2 PROFINET Setting 44 3 5 3 Modbus Setting 45 3 5 4 Mapping Overview 48 3 6 SYSTEM MANAGEME...

Страница 10: ...JetLink 1102 JetLink 1302 User Manual 10 1 Product Overview 1 1 SPECIFICATIONS...

Страница 11: ...n 1 System LED panel See LED Indicators on Page 15 for further details 2 Default Press less than 5 seconds to restart device press over 5 sec onds to reset to factory default 3 Ethernet port RJ45 port...

Страница 12: ...anel See LED Indicators on page 15 for further details 2 Default Press less than 5 seconds to restart device press over 5 sec onds to reset to factory default 3 Ethernet port RJ45 port for Modbus TCP...

Страница 13: ...JetLink 1102 JetLink 1302 User Manual 13 1 2 2 Rear View Figure 1 4 Rear View...

Страница 14: ...g holes Screw holes x4 used in the installation of a wall mounting plate 3 Ground terminal Screw terminal used to ground chassis 1 2 4 Bottom View Figure 1 6 Bottom View No Item Description 1 Wall mou...

Страница 15: ...ackup function is disabled Off System is no working Protocol LED EtherNET IP EI Orange Reserved Green Blinking IO connection do not establish Steady on IO connection establish Modbus MS Orange Blinkin...

Страница 16: ...disabled Off System is no working Protocol LED PROFINET PN Orange Blinking PLC connection do not establish Green Blinking Indicated by TIA portal Steady on IO connection establish Modbus MS Orange Bl...

Страница 17: ...JetLink 1102 JetLink 1302 User Manual 17 1 3 DIMENSIONS Figure 1 7 Dimensions JetLink1102 1302...

Страница 18: ...unre stricted Without proper airflow the fieldbus gateway can overheat To prevent performance degradation and damage to the fieldbus gateway make sure there is clearance at the top and bottom and aro...

Страница 19: ...ng make sure to allow for enough space to properly install the cabling 2 3 1 1 Installing the DIN Rail Mounting Kit 1 Position the rear panel of the fieldbus gateway directly in front of the DIN rail...

Страница 20: ...or an illustration of a completed DIN installation proce dure 3 Grasp the bottom of the fieldbus gateway and slightly rotate it upwards If there is resistance the fieldbus gateway is correctly install...

Страница 21: ...wer is removed from the fieldbus gateway and disconnect all cables and connectors from the front panel of the fieldbus gateway 2 Push down on the top of the DIN rail clip release tab with your finger...

Страница 22: ...to remove the DIN rail plate 1 Rotate the device to the rear side and locate the DIN mounting plate 2 Remove the screws securing the DIN mounting plate to the rear panel of the fieldbus gateway 3 Rem...

Страница 23: ...dition to the screws 9 Insert the wall sinks into the walls 10 Insert the screws into the wall sinks Leave a 2 mm gap between the wall and the screw head to allow for wall mount plate insertion Note M...

Страница 24: ...JetLink 1102 JetLink 1302 User Manual 24...

Страница 25: ...hielded cabling Shielded cabling may be used to provide further protection Maximum cable length 100 meters for 10 100BaseT Straight thru Cable Wiring Cross over Cable Wiring Pin 1 Pin 1 Pin 1 Pin 3 Pi...

Страница 26: ...exFAT file systems are supported 2 6 1 Installing a MicroSD Card 1 Before continuing make sure the file system on the microSD card is set to FAT32 or exFAT If necessary format the microSD card and the...

Страница 27: ...ault and power off Insert a microSD card with an valid configuration file Power on the device The device will use the valid configuration settings in the microSD card Backup management Device setting...

Страница 28: ...use any other power components except those specifically designated for the fieldbus gateway device Caution Disconnect the power cord before installation or cable wiring The fieldbus gateways can be...

Страница 29: ...put wiring Label all wiring and cabling to the various devices for more effective manage ment and servicing Note Routing communications and power wiring through the same conduit may cause signal inter...

Страница 30: ...ssions By connecting the ground terminal by drain wire to earth ground the fieldbus gateway and chassis can be ground Note Before applying power to the grounded fieldbus gateway it is advisable to use...

Страница 31: ...except those specifically designated for the fieldbus gateway device Warning Power down and disconnect the power cord before servicing or wiring the fieldbus gateway There are two power inputs for nor...

Страница 32: ...screws 4 Insert the negative positive DC wires into the V V terminals of PW1 If setting up power redundancy connect PW2 in the same manner 5 Tighten the wire clamp screws to secure the DC wires in pla...

Страница 33: ...ere is no gap between the terminal block and the terminal receptor the ter minal block is seated correctly 2 8 RESET BUTTON Reset configuration to factory default Press and hold Reset button for 5 sec...

Страница 34: ...us gateway setup before connecting it to the network 1 Launch your web browser on a computer 2 In the browser s address bar type in the fieldbus gateway s default IP address 192 168 10 1 The login scr...

Страница 35: ...menu lists information such as Model Firmware version MAC Address and more pertaining to the system The information is for review only To modify the device information see the respective item within...

Страница 36: ...e of the device IP Address Displays the assigned IP address of the device Subnet Mask Displays the assigned subnet mask of the device Gateway Displays the assigned gateway of the device Item Descripti...

Страница 37: ...e informational only UP Time Originator Receive Address O T Packets T O Packets O T Con nection ID O T RPI ms T O Connection ID and T O RPI ms The following tables are only available for JetLink 1302...

Страница 38: ...of EtherNet IP data for JeyLink1102 and Profinet slot data for JetLink1302 To access this page click Overview Data View The following figure displays the menu as found in the JetLink1102 Figure 3 8 Ov...

Страница 39: ...Data View JetLink1302 3 3 NETWORK SETTING 3 3 1 IP Setting The IP Setting menu allows you to select a static or DHCP network configuration The Static displays the configurable settings for the static...

Страница 40: ...option to use same IP address setting on Modbus TCP and EtherNet IP interface In this mode the Ethernet ports of Modbus TCP and EtherNet IP are bridged so the traffic can be forwarded between these in...

Страница 41: ...P and EtherNet IP interface use the same IP address setting Check the option to use same IP address setting on Modbus TCP and EtherNet IP interface In this mode the Ethernet ports of Modbus TCP and Et...

Страница 42: ...the baud rate The value should conform to the current transmission speeds of connected devices when setting the baud rate Priority Click the drop down menu to select the parity None Odd Even Mark or S...

Страница 43: ...us exception codes The EtherNet IP Setting page is only available for JETLINK1102 To access this page click Protocol Setting EtherNet IP Setting The following table describes the items in the previous...

Страница 44: ...to PROFINET I O Slot There are two types of slot mappings as defined in the following figure The PROFINET Setting page is only available for JETLINK1302 To access this page click Protocol Setting PROF...

Страница 45: ...he Modbus command for each slave device Each slave device may need more than one command for communication so it is necessary to add all the commands manually To access this page click Protocol Settin...

Страница 46: ...JetLink 1102 JetLink 1302 User Manual 46 To add a new transaction Figure 3 18 Protocol Setting Modbus Setting Add The following table describes the items in the previous figure...

Страница 47: ...JetLink 1102 JetLink 1302 User Manual 47...

Страница 48: ...ter Name Adapter Function Code Adapter Size Byte and Adapter Byte range The ensuing table for Transaction table settings are informational only Name Quantity Class Instance Attribute and Access The fo...

Страница 49: ...t the system System Management Apply Configuration to save the updates 3 6 2 Backup Manager The Backup Manager page allows you to backup configuration from the device or restore configuration file to...

Страница 50: ...Figure 3 22 System Management Upgrade Manager The following table describes the items in the previous figure 3 6 4 Reset System To access this page click System Management Reset System Click Reset to...

Страница 51: ...made since the last time you issued a save will be lost Figure 3 24 System Management Reboot Device 3 6 6 Apply Configuration To access this page click System Management Apply Configuration Click App...

Страница 52: ...s Traffic Catcher The Modbus Traffic Catcher page shows only data sent and received by Modbus To access this page click Tools Modbus Traffic Catcher Figure 3 26 Tools Modbus Traffic Catcher The follow...

Отзывы: