12
3
Management
3-2 How to check malfunctions and to manage and repair them
Symptoms
Checking
Measures
Flashing of front start button
Please check displays of number
board on front operational panel
Refer to alarm functions of
malfunctions
Snow ice is not made
No supply of water
No stop of ice making
material supply
Water flows out to the
product floor
① Please check shortage of
materials in ice making
material container
② Please check shortage of
materials in ice making dish
① Water supply pressure is low?
② Is water supply stopped?
③ Is water supply device broken?
① Is ice making dish correctly put?
② Is material touched to material
detection sensor bar?
① Is drainage hose detached?
② In spite of operation stop,
water supply continues
① Supply materials into ice
making material container
② Supply materials into ice
making dish
③ Check if materials are left in
material detection sensor bar
④ Contact to the service center
① Install pressure device
② After water supply resumed,
please use it
③ Contact to the service center
① Put ice making dish correctly
② Adjust the height of sensor bar
③ Contact to the service center
① Put in drainage hose
② Contact to the service center
※ Please do not dismantle, repair or remodel the machine
※ In case of abnormal operation in the machine, please contact to the service center
【ERROR】Functions to alarm malfunctions
Display window shows code number of
malfunction
Code Number
Contents of Malfunction
Measures
E1
Lack of Materials
① Check if materials is short in ice making material tank
② Check whether there is malfunction of ice making material
supply device
③ If malfunction continues, contact to the service center
E2
Condenser temperature is over
60 Celsius degree(Overheat)
① Check if cooling water is lack or water supply is stopped
② Check whether pressure automatic valve is normally
operated
③ If malfunction continues, contact to the service center
※ When completing error measures, please touch Start/Stop button for one second, it returns to default
operation waiting status
Содержание NSM-25G0MW
Страница 14: ...14 Memo...