background image

4

IV. Product Identification and Labels

Each Kooltronic Air Conditioner includes an identification label. This label provides:

Model Number

Serial Number

Electrical power characteristics
Maximum and minimum ambient operating temperatures
Cooling capacity
Heating capacity
Type and amount of refrigerant required for recharging
Design Pressure
Filter Part Number
Customer Part Number
Final Assembly Number
Manufacturing Order Number

We recommend you copy this information from your unit.

MODEL NO.

SERIAL NO.

COOLING

AMBIENT TEMP

HEATING.

VOLTS.

FREQ.

PH.

F.L.A.

MIN.

o

F

MAX 

o

F

F.L.A.

COOLING BTU

HEATING BTU

REFRIGERANT

Oz.

DESIGN PRESSURE P.S.I.G.

MAX.

LOW

HIGH

FUSE SIZE

FILTER P/N

CUSTOMER PART NO.

FINAL ASSEMBLY NO.

MFG. ORDER NO.

SPECIAL PURPOSE AIR CONDITIONER

NEMA/EEMAC/UL50 BY UNDERWRITERS LABORATORIES, INC.

TYPES 3R & 12 INTERFACE TO THE ELECTRICAL ENCLOSURE ONLY

NEMA/EEMAC/UL50 BY UNDERWRITERS LABORATORIES, INC.

TYPE 1 SPECIAL PURPOSE AIR CONDITIONER EQUIPMENT

COMPARTMENT ONLY

Air  Conditioner

➀➁ 

When ordering parts, specify the Model Number and Serial Number.

➂ 

Before operating, be sure that the power source matches these requirements.

Use of incorrect type or amount of refrigerant will adversely affect performance and may damage the unit.

Make sure that these parameters are met. Failure to do so may result in permanent damage to the unit.

1

2

3

3

3

3

3

4

4

5

6

7

7

8

8

3

10

SERVICE AIR FILTERS REGULARLY

ALLOW 5 MIN. BEFORE RESTARTING AFTER SHUTDOWN

UNAUTHORIZED SERVICE OR MODIFICATION VIOLATES WARRANTY

ALL MOTORS ARE THERMALLY PROTECTED

THIS PRODUCT IS PROTECTED BY ONE OR MORE OF THE FOLLOWING PATENTS:  3,019,965      

3,120,166  3,211,360  3,559,728  3,807,493  AND OTHER PATENTS PENDING

MANUFACTURED BY:

KOOLTRONIC, INC.

PENNINGTON, NJ

VENTURA, CA

11

12

1

2

3

4

5

6

7

8

10

11

12

9

9

Содержание KAC4P3777R

Страница 1: ...ONDITIONER IT IS IMPORTANT THAT INSTALLATION INSTRUCTIONS DOCUMENT NUMBER 900 090 00 SHIPPED WITH THE UNIT BE READ AND UNDERSTOOD THOROUGHLY KOOLTRONIC INC 30 Pennington Hopewell Road Pennington NJ 08...

Страница 2: ...Introduction Kooltronic Air Conditioners are designed to provide a cool dehumidified environment for your electronic components There are models to fit virtually all sizes and shapes of electronics en...

Страница 3: ...ate in a horizontal position only This placement must be done a minimum of 5 minutes prior to operating in order to allow the compressor oil to drain to the compressor sump area CAUTION 3 Before opera...

Страница 4: ...LABORATORIES INC TYPES 3R 12 INTERFACE TO THE ELECTRICAL ENCLOSURE ONLY NEMA EEMAC UL50 BY UNDERWRITERS LABORATORIES INC TYPE 1 SPECIAL PURPOSE AIR CONDITIONER EQUIPMENT COMPARTMENT ONLY Air Conditio...

Страница 5: ...hrough the evaporator coil is transferred by the compressed refrigerant to the condenser coil Ambient air is then passed through the condenser coil where it absorbs the heat and is then discharged to...

Страница 6: ...he unit receptacle labeled Thermostat Power 5 Turn the electrical power on 6 Verify that the evaporator blower is running The remote control includes a compressor time delay After operating three 3 mi...

Страница 7: ...two upper studs Run the unit power cord through the enclosure cutout 5 Secure the unit to the enclosure using the remaining 4 supplied 1 4 bolts and nuts the two saved 1 4 nuts and the supplied 7 was...

Страница 8: ...4 3 LOCK WASHER 3 1 2 3 NOTE CUSTOMER TO INSTALL GASKET AS SHOWN START AND END GASKET MATERIAL HERE USE ONE CONTINUOUS PIECE OF GASKET AROUND PERIMETER OF UNIT BEND GASKET AROUND THE CORNERS DO NOT S...

Страница 9: ...2 11 50 292 1 1 4 20 MOUNTING STUD TYP 2 PLACES POWER CORD 1 4 20 CAGE NUTS TYP 4 PLACES 7 50 190 5 13 00 330 2 8 24 209 3 9 41 239 0 Drawings and Dimensions KAC4P3777R Dimensions inches mm are for re...

Страница 10: ...aporator Impeller Capacitor 0452 06 Condenser Coil 0666 66 Evaporator Coil 0667 64 Heater 0718 22 Filter 8001F Heating Thermostat 0750 132 Cooling Thermostat 0750 131 Standard Features Low Temperature...

Страница 11: ...11 Wiring Schematic WD 1327 KAC4P3777R WD 1327...

Страница 12: ...12 Wiring Schematic WDNCRMAN KAC4P3777R WDNCRMAN...

Страница 13: ...EVAPORATOR BLOWER BK GN CAP HEATER COOLING T STAT THERMAL CUTOUT HEATER T STAT LIMITER SWITCH PRESSURE SWITCH CONDENSER IMPELLER RELAY NC NO CONDENSER IMPELLER R C S O L CAP COMPRESSOR WD 1328 Rev A K...

Страница 14: ...y A Filter and condenser coil service If an optional filter is installed on externally mounted air conditioners filter should not be used for internal mounted air conditioner the rear panel must be re...

Страница 15: ...running Low Line Voltage Check Nameplate Voltage against supply Voltage Compressor and Condenser Blower do not run Return temperature is Failed Compressor Check Compressor wire connections above set p...

Страница 16: ...l difference between return and Coil clogged supply air is less than 10 F Evaporator Blower Condenser Loss of Refrigerant Locate and repair leak Blower and Compressor are running Ice on Evaporator Coi...

Страница 17: ...was received by customer Number of parts to be returned Product description model and serial number Reason for return Action requested Contact name telephone FAX numbers and e mail address Pack unit i...

Отзывы: