background image

KT-1E----TECHNICAL SPECIFICATION

KT-1E----TECHNICAL SPECIFICATION

KT-1E –IMPORTANT REMINDERS

Please read the manual carefully and operate the cooler before use.
A) Use the machine in the following condition :
1- Temperature: 18°C ~ 45°C; Water Temperature: < 45°C.
2- Electric voltage must not exceed the required volt (+/-) 5%.
3- No pollution of surrounding.

B) The circuit of the cooler must be properly connected and protected to
prevent mouse bites. Do not trample and over-stretch the wire, it may cause
short circuits. Wrong electric voltage of wrong socket will cause danger of
electric shock.

C) Do not use wrong circuit or other wire metal made of other materials
which may cause machine malfunction or explosion.

D) If the product is not operating well or may have malfunctioned, please
inform the distributor or dealer.

E) other tips for cooler use :
1- Keep the doors and windows a little opened to bring in fresh air from

outside when cooler is operating.

2- Check water level in the water tank and supply water when the red light

on LCD panel is flashing.

3- Fresh water is suggested to be replaced in the tank for one or two times

in the beginning period of cooler operation.

4- Push the cooler carefully if the tank is full with water, especially if the

floor is rather rough.

PARAMETER / MODEL

KT-1E

Max Airflow (M

3

/H)

6000

Power supply/Frequency (V/HZ)

220-240/50

Power Consumption (W)

290

Fan Style

Axial

Water Consumption (L/H)

4-6

Water Capacity (L)

60

Dimension (L*W*H) (mm)

860×500×1200

Weight (KG)

32

Effective Cooling Area (M

2

)

30-50

Содержание KT-1E

Страница 1: ...evel indicator reaches the bottom level the inlet valve will open automatically to add water When the water reaches the indicated full level the valve will close automatically KT 1E APPLICATION Public places Company office supermarket shop family big living room public waiting room hospital school workshop workers dormitory temple outdoor teahouse coffee bar restaurant recreation facilities etc Ma...

Страница 2: ... may cause machine malfunction or explosion D If the product is not operating well or may have malfunctioned please inform the distributor or dealer E other tips for cooler use 1 Keep the doors and windows a little opened to bring in fresh air from outside when cooler is operating 2 Check water level in the water tank and supply water when the red light on LCD panel is flashing 3 Fresh water is su...

Страница 3: ...ars the setting time of cooler operation finish is cancelled 6 Water supply Clean water must be used Pour water into water inlet on the right side of the unit slowly to avoid spillage Water inlet on left side can also be used to connect water tap for automatic water supply WARNING 1 If the supply cord is damaged it must be replaced by the manufacturer of its service agent or a similarly qualified ...

Страница 4: ...ized water as it may cause damage to the pad 2 Clean the pad from the inner side to out side of pad inner side is towards motor Never use any liquid detergent 3 Unscrew the drainage lid to let dirty water flow out then clean the water tank thoroughly with soft cloth Wash off dirt on the water sensor water pump and the float valve 4 Use mild soap and soft clean cloth when cleaning the cooler casing...

Страница 5: ...oard goes wrong Panel goes wrong Change the main control board Change the panel Water leak of draining valve Draining valve is loose Screw slightly Air diffuser doesn t run Synchronous motor is burnt out Crankshaft is broken off Crankshaft and swing bar fall off Change synchronous motor Change crankshaft Fix crankshaft and swing bar again Water drops splash out of the air diffuser Water pipe falls...