110013961AA
date of change: 18.08.2008
page: 18/19
Group
]
PrC
(parameter of the compressor protection and switch-on delay)
Par.
Description
Range
Def.
PSC
Compressor protection mode:
1= switch-on delay
2= delay after switching-off
3= delay between switching-on
1 - 2 - 3
2
PtC
Time compressor protection
OFF ÷ 99.59
min.sec
01.00
LtC
Minimum compressor switch-on duration
OFF ÷ 99.59
min.sec
OFF
od
Activation delay of the outlets when switching-on the units OFF ÷ 99.59
min.sec
OFF
O N
O u t
o ff
P tC
P tC
P tC
S P
T e m p .
" P S C " = 2
tim e
H S E t
O N
O N
o ff
o ff
P r 1
Group
]
Out
(parameter of the configuration of the outlets)
Par.
Description
Range
Def.
Out1
Operating configuration outlet OUT1
Out= temperature control (compressor)
-
Refers to Pr1 [SP, HI, LO]
dEF= defrost instrument
FAn= fans
AuS= auxiliary outlet
ALt= confirmable alarm
(pressing of any button always resets the alarm
AL= standard alarm
ALL= stored alarm
(alarm remains in the background, also if alarm
does not exist any more, reset with any button only
if alarm condition is not existing any more.
OFF= no function
OFF/Out/dEF/
FAn/AuS/ALt/
AL/ALL/ -ALt/
-AL/ -ALL
Out
Out2
Operating configuration outlet OUT2
dEF= defrost instrument
-
Refers to Pr2 at “cooling” [tEdF, tSdF]
-
Refers to time [dint, dEFE]
-
Refers to Pr1 at „heating“
{LO --> on / nr --> off / HO --> after prog.}
OFF/Out/dEF/
FAn/AuS/ALt/
AL/ALL/ -ALt/
-AL/ -ALL
dEF
Out3
Operating configuration outlet OUT3
FAn= fan
-
refers to Pr2 [FLt, Fct]
-
FCOF, FEdF
OFF/Out/dEF/
FAn/AuS/ALt/
AL/ALL/ -ALt/
-AL/ -ALL
FAn