26
10.2 Errors during the operation:
If there is an error during the operation, the
KOLIBRI will show you the error like you can see in
the table below.
Operation error: LED green is off, LED red flashes
the issue out:
blink-
code
description
process
1
Voltage not in operation range
Please check battery /
motor
2
Current not in operation range
Please check battery /
motor
3
Overtemperature
Please improve cooling
4
Voltage or current of the BEC out
of the range
Please check your
servos
5
Limit of programmed capacity
reached
6
No RC Signal
Please check the
connection between
ESC (Master Cable)
and receiver
7
Motor is not able to handle this
power
Please restart your ESC
8
PowerVoltageDetector of the
processor has detected
Please restart your ESC
9
No Motor values
Please check motor and
connections. Then
restart your ESC
10.3 Warnings
If there is a warning reached, the KOLIBRI shows it
by the following codes:.
LED red and LED green flashing fast = orange
blink-
code
description
1
Variance is too big or RPM not in range
2
Cut Off
3
Limit of battery discharge reached
4
Watchdog Reset has detected
5
Internal error
6
Programmed undervoltage is reached
7
Programmed current limit reached
8
Programmed MOS FET Temperature limit reached
9
Programmed BEC Temperature limit reached
10
programmed BEC current reached
11
Programmed limit of battery discharge reached
Содержание KOLIBRI 140 LV