MSH8900
www.symkloud.com
// 39
3.1.
Establishing a Serial Connection
Use the RJ45 to DB9 adapter provided with
the platform to connect a (non-crossover)
Ethernet cable to establish a serial
the RJ45 console port of the hub with the
active ShMC (faceplate marking "1010"; see
Figure 3).
In MS2900 platform, the hub with the
active ShMC is the one with the solid green
Power LED (see Figure 3). The hub with the
standby ShMC has the blinking green Power
LED.
Configure a serial console tool (e.g.:
) with the
correct COM-port for your system using the following
parameters:
Speed (Baud) = 115200
Data bits = 8
Stop bits = 1
Parity = none
Flow Control = none