Kontron CP347 Скачать руководство пользователя страница 24

CP347 – User Guide, Rev. 1.3  

 

www.kontron.com 

 

// 24 

 

4/

 

Installation 

4.1.

 

Hardware Installation 

Before installing the CP347 in a CompactPCI backplane slot, read this installation chapter thoroughly for guidelines on 
positioning, installing and removing the board.  

The CP347’s front panel should be safely secured by screwing the front panel to the chassis to avoid loosening of the 
board through vibration and to ensure an adequate earth connection. 

 

 

 

 

 

ESD Sensitive Device! 
This CompactPCI board contains electrostatic sensitive devices. Observe the necessary 
precautions to avoid damage to your board: 

 

Discharge your clothing before touching the assembly.  

 

Discharge tools before use. 

 

Do not touch components, connector pins or traces. 

 

If working at an anti-static workbench, use the professional discharging equipment. 

 

 

Board Location in the System 

4.1.1.

It is possible to install the CP347 in any CompactPCI backplane slot except for the system master slot. Consider the 
board’s location within a system carefully. Factors such as the number of CP347 boards, their locations in a given 
system, and the operating system in use, may cause applications to have difficulty identifying boards properly. This 
includes board replacement, board movement to another slot, and other possible configuration changes to the initial 
system.  

If the position of the board is changed, verify the proper operation of the system before putting the system into 
operation. 

 

 

 

When configuring a system, install all boards in the system prior to installing drivers or 
other board related software. Failure to do so may result in the non-identification of a given 
board or boards. 

 

 

 

Hot Swap Capabilities 

4.1.2.

The CP347 is not hot swappable. Read the following caution notice carefully before installing or removing the CP347 
from a system. 

 

 

 

 

 

 

CP347 Not Hot Swappable 
Switch off the CompactPCI system power before installing a board classified as not hot-
swap capable in a free CompactPCI slot. Failure to do so could result in personal injury and 
may damage your board or system.

 

 

   

Содержание CP347

Страница 1: ...USER GUIDE CP347 Doc User Guide Rev 1 3 Doc ID 1060 5099...

Страница 2: ...CP347 User Guide Rev 1 3 www kontron com 2 This page has been intentionally left blank...

Страница 3: ...be suitable for the specified use without further testing or modification Kontron expressly informs the user that this user guide only contains a general description of processes and instructions whic...

Страница 4: ...s contact information on the last page of this user guide or visit our website CONTACT US Customer Support Find Kontron contacts by visiting http www kontron com support Customer Service As a trusted...

Страница 5: ...cribed by the law may endanger your life health and or result in damage to your material ESD Sensitive Device This symbol and title inform that the electronic boards and their components are sensitive...

Страница 6: ...efore performing any work on this product Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last cable to be disconne...

Страница 7: ...ssary to store or ship the product then re pack it in the same manner as it was delivered Special care is necessary when handling or unpacking the product See Special Handling and Unpacking Instructio...

Страница 8: ...l I O Connector 20 2 3 1 Front Panel Adapter Cable 37 Pin to 4x 9 Pin 21 2 3 2 JTAG Connector 21 2 3 3 CompactPCI Connector 21 2 3 4 3 Configuration 22 3 1 Hardware Configuration 22 Serial Mode Config...

Страница 9: ...in D Sub Front Panel Connector Pin Assignment 21 Table 7 Serial Mode DIP Switch CP347 Configuration 22 Table 8 RS422 RS485 Termination Jumper Settings 22 Table 9 RS485 Transceiver Control RTS and DTS...

Страница 10: ...eparate serial I O channeling it is possible to connect a front panel adapter to the 37 pin front panel connector This adapter terminates on the user side with four male 9 pin D Sub connectors one per...

Страница 11: ...CP347 User Guide Rev 1 3 www kontron com 11 1 2 Board Diagrams Figure 1 CP347 Functional Block Diagram...

Страница 12: ...S232 or RS 422 RS485 serial interfaces controlled and converted by a PCI to serial controller For the 37 pin D Sub connector s pin assignment see Chapter 2 3 1 Front Panel Serial I O Connector 1 2 1 1...

Страница 13: ...n3 12 pin JTAG ISP connector 2 3 3 14 Con1 CompactPCI connector J1 in the CompactPCI specification 2 3 4 Item Configurable Components Description Chapter 2 R16 R17 R18 R19 R20 R21 R22 R23 8x 0 resisto...

Страница 14: ...3 1 3 23 JP1 JP2 JP3 JP4 JP5 JP6 JP7 JP8 Bus termination solder jumpers Listed from top to bottom 3 1 2 Item Components Description 7 U7 CPLD 9 U11 Voltage translator 12 U3 U4 U8 U12 U16 U20 U22 U25 D...

Страница 15: ...ftware Serial Data Rates Up to 115 2 kbps Programmable Data Formats Up to 64 byte transmit and receive FIFOs Automatic RTS CTS or DTR DSR flow control Automatic Xon Xoff software flow control Automati...

Страница 16: ...rature Extended range 40 C to 85 C In a passive cooled system the maximum ambient temperature is 63 C Storage Temperature 55 C to 125 C Humidity 93 RH non condensing Operating Altitude Up to 2000 m Th...

Страница 17: ...2 Electrostatic Discharge EN 61000 4 3 RF electromagnetic fields EN 61000 4 4 Burst EN 61000 4 5 Surge EN 61000 4 6 Conducted interferences Safety EN 60950 1 UL CSA 60950 1 Electrical safety IT equipm...

Страница 18: ...ates the serial channels from the CompactPCI interface The CP347 provides a universal CompactPCI interface and can work properly with 5 V and 3 3 V PCI V I O signaling 1 7 Related Publications Table 4...

Страница 19: ...via the standard PCI interface provided directly on the Exar XR17D154 Logical control of the CP347 serial communication operation is accomplished via the Exar XR17D154 command and status registers tha...

Страница 20: ...ront Panel Pin RS232 Direction RS232 RS485 Half Duplex RS422 Full Duplex Front Panel 37 Pin D Sub Connector 0 FE01 37 In DCD RxD FE02 36 In RXD FE03 35 Out TXD TRxD TxD FE04 34 Out DTR FE06 18 In DSR...

Страница 21: ...Sub Front Panel Connector Pin Assignment D Sub Pin RS 232 Signal RS 422 Signal Full Duplex RS 485 Signal Half Duplex 1 DCD RxD NC 2 RxD NC NC 3 TxD TxD TRxD 4 DTR NC NC 5 GND GND GND 6 DSR RxD NC 7 R...

Страница 22: ...ngs where switch setting are either On or Off and resistor setting are either Open or Set Table 7 Serial Mode DIP Switch CP347 Configuration Channel Channel 0 Channel 1 Channel 2 Channel 3 Switch Resi...

Страница 23: ...s an assembled 0 resistor Table 9 RS485 Transceiver Control RTS and DTS Resistor Configuration Channel 0 Channel 1 Channel 2 Channel 3 R32 R33 R45 R44 R46 R47 R38 R37 RTS Signal Controls DE RE default...

Страница 24: ...for the system master slot Consider the board s location within a system carefully Factors such as the number of CP347 boards their locations in a given system and the operating system in use may cau...

Страница 25: ...eeding Do not push the board into the backplane connectors Use the ejector handles to seat the board into the backplane connectors 2 Insert the board into the designated slot carefully until it makes...

Страница 26: ...able CP ADAP CP346 CP347 can be connected to the CP347 s 37 pin D Sub front panel connector The front panel adapter terminates on the user side with four male 9 pin D Sub connectors that include the s...

Страница 27: ...ilable for the CP347 For more detailed driver installation information refer to the relevant CP347 driver documentation For more information contact Kontron Support Install all boards required for the...

Страница 28: ...Controller Style KVM Keyboard Video Mouse MEI Management Engine Interface NCSI Network Communications Services Interface OSI Open System Interconnection PCI Peripheral Component Interface PCIe PCI Ex...

Страница 29: ...rtfolio of secure hardware middleware and services for Internet of Things IoT and Industry 4 0 applications With its standard products and tailor made solutions based on highly reliable state of the a...

Отзывы: