CP347 – User Guide, Rev. 1.3
www.kontron.com
// 16
1.4.
Environmental Considerations
Table 2: Environmental Specification
Environmental Specification
Operating Temperature
Standard range
0°C to +70°C
In a passive cooled system, the maximum ambient
temperature is +48°C.
Operating Temperature
Extended range
-40°C to +85°C
In a passive cooled system, the maximum ambient
temperature is +63 °C.
Storage Temperature
-55 °C to +125 °C
Humidity
93 % RH non-condensing
Operating Altitude
Up to 2000 m
The difference between ambient temperature and the temperature inside the system must
be considered.
Forced air-cooling is required and must be considered in the system.
If the system is operated in a dust-prone environment, an air filter must be considered for
dust protection.