Configuration
CP6000
Page 4 - 18
© 2005 Kontron Modular Computers GmbH
ID 27942, Rev. 05
2794
2.05.UG.VC.051020/17275
8
P R E L I M I N A R Y
4.5.7
CPCI Master Reset
The CPCI master reset register describes the routing of the reset signal from the CompactPCI
interface to the local reset controller if the board is installed in a peripheral slot. If the board is
installed in a system slot, the reset is always an output. If the reset is disabled, the CP6000
ignores the reset signal from the CompactPCI interface.
Table 4-21: CPCI Master Reset Register
REGISTER NAME
CPCI Master Reset Register
ACCESS
ADDRESS
0x285
W
BIT POSITION
MSB
7
6
5
4
3
2
1
0
LSB
CONTENT
Res.
Res.
Res.
Res.
Res.
Res.
Res.
CRST
DEFAULT
0
0
0
0
0
0
0
0
BIT
NAME
VAL
DESCRIPTION
0
CRST
0
Disable the reset routing from the CompactPCI interface
1
Enable the reset routing from the CompactPCI interface
1
0
Reserved
2
0
Reserved
3
0
Reserved
5
0
Reserved
6
0
Reserved
7
0
Reserved