4.4.14
Serial Over LAN Configuration Register
Via the Serial Over LAN Configuration Register the MMC can configure a number of SOL
settings. This register is read only and can be configured only by the MMC.
Table 4-21: Serial over LAN Configuration Register
REGISTER NAME
SERIAL OVER LAN CONFIGURATION REGISTER
ADDRESS
0x28E
BIT
NAME
DESCRIPTION
RESET
VALUE
ACCESS
7-4
SCOM
Host COM1 port configuration for Serial over LAN
0000
R
3-0
SOLC
Serial over LAN configuration
0000 = 82571EB emulated serial port is used
0001 = MMC using host COM1 port for Serial Over LAN
If the MMC is using the host COM1 port for Serial Over LAN, both
bits (SCOM and SOLC) must be set to ’1’.
0000
R