2. Troubleshooting and Maintenance
3-11
M
S
P
30
00 P
rin
ter
Ch
apte
r 3
Clearing a Misfeed from inside the Printer
Open the Upper Unit by pulling the
Upper Unit Lock Release Lever
forward.
NOTE
Push the Print Tray in before opening the
Upper Unit.
Remove the Imaging Cartridge.
NOTE
Be sure to cover the Imaging Cartridge
with a heavy cloth to protect it from light
when it is removed from the Printer.
If the misfeed occurred before the
sheet of paper entered the Fusing
Unit, gently pull the misfed sheet up
and out as shown.
If the misfeed occurred after the sheet
of paper entered the Fusing Unit,
gently pull the misfed sheet toward
you and out as shown.
NOTE
• Since the toner has not yet been fixed
onto the sheet of paper, be careful not to
soil your hands or clothes when pulling
out the misfed sheet.
• Do not remove the misfeed by pulling on
the sheet of paper toward the output end
of the Fusing Unit as shown.
Reinstall the Imaging Unit and close
the Upper Unit.
1
2
3
4